COUNTER TOP NOTCH DETAIL
Only required if island counter top overhangs the face of the island
MODEL-SPECIFIC BTU OUTPUTS & MAX. RUNS FOR APPLIANCES
MODEL
VQGI5301/VQGFS5301 (N/L)SS
VQGI5361/ VQGFS5361 (N/L)SS
VQGI5421/ VQGFS5421 (N/L)SS
VQGI5541/ VQGFS5541 (N/L)SS
C
A A
5"
3"
4.5"
B
MODEL-SPECIFIC BTU OUTPUTS
H BURNER (Btu)
ROTISSERIE (Btu)
1 @ 25,000
1 @ 14,000
2 @ 25,000
1 @ 14,000
2 @ 25,000
1 @ 16,000
3 @ 25,000
2 @ 14,000
MAXIMUM RUNS FOR ALL
APPLIANCES ON SUPPLY LINE
Run Length
Max BTU for all
3/4" Pipe (in feet)
Appliances on line
10
20
30
40
50
60
70
80
PROSEAR™ (Btu)
1 @ 21,000
1 @ 21,000
1 @ 21,000
1 @ 21,000
360,000
245,000
198,000
169,000
150,000
135,000
123,000
115,000
INSTALLATION / USE & CARE
TOTAL INPUT
60,000 Btu/Hr
85,000 Btu/Hr
87,000 Btu/Hr
124,000 Btu/Hr
|
9