FACTORY SETTINGS

The device leaves the factory with a series of preset parameters which may be changed according to the user's requirements. Each change of
the settings is automatically saved in the memory and, if desired, it is always possible to restore the factory conditions.
9.1

Restoring the factory settings

It restores the value of all configuration parameters to factory default values.
NOTE: Once the factory values have been restored it will be necessary to reset all the parameters that characterise the system (gains, setpoint
pressure, etc.) as at the first installation.
Identifying code
SP
RP
OD
TB
T2
GP
GI
RM
AE
AF
AY
Power Shower Duration
Sleep Mode Enabling
Sleep Mode start time
Sleep Mode Duration
Float function
Pump stop based on level
Minimum level for pump stop
L1 tank
L2 tank
10

TROUBLESHOOTING

Before starting to look for faults it is necessary to disconnect the power supply to the pump (take the plug out of the socket). If the
power cable or any electrical part of the pump is damaged, the repair or replacement must be carried out by the manufacturer or
by their technical assistance service, or by a person with equivalent qualifications, so as to prevent any risk.
FAULTS
The pump does not turn on or
does not stay on.
La pompa non si arresta.
The flow rate is insufficient.
The pump does not deliver
water.
Factory settings
Description
Setpoint pressure [bar]
Pressure decrease to restart [bar]
Type of plant
Blockage time due to dry operation [s]
Delay in switching off [s]
Proportional gain coefficient
Integral gain coefficient
Maximum speed [rpm]
Anti-blocking function
Antifreeze
Anticycling Function AY
Power Shower function duration [hh:mm]
Sleep Mode function enabling
Sleep Mode function start time
Sleep Mode function duration [hh:mm]
Enabling float
Enabling pump stop based on minimum tank level
Level below which the pump stops [cm].
Setting tank side 1 or diameter [cm]
Setting tank side 2 [cm]
Table 6 Factory settings
PROBABLE CAUSES
Pump is not powered.
No water.
Utility at a level higher than the system
restarting pressure level.
Leak in the system.
Impeller or hydraulic part clogged.
Air getting into the suction pipe.
Suction clogged.
Suction pipe diameter insufficient.
The suction grid or the pipes are blocked.
The impeller is worn or blocked.
The head required is higher than the pump's
characteristics.
ENGLISH
Check power supply.
Restore the water level.
Increase the system restarting pressure level by
increasing SP or decreasing RP.
Check the system, find and eliminate the leak.
Dismantle the system and remove the
obstructions (assistance service).
Check the suction pipe, find and eliminate the
cause of air getting in.
Remove the obstructions
Use a pipe with diameter at least 1"
Remove the obstructions.
Replace the impeller or remove the blockage.
26
Value
Installation Memo
3.0
0.5
Rigid
15
10
0.5
1.2
5000
Enabled
Enabled
Disabled
30'
Disabled
23:00
7 h
Enabled
Disabled
0
0
0
REMEDIES