Performance
SmartWater
TM
Data Sheet
o.som mo ,sJ
Filtration System-GE
MWF Cartridge
The concentration
of the indicated substances
in water entering the system was reduced to a concentration
less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International
against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity
300 Gallons (1,135 Liters).
Contaminant
Reduction
Determined
SubStance Tested
NSF Specified
Avg_
for Reduction
Average tnfluent
2.0 mg/L
Challenge Concentration
2.0 mg/L ± 10%
Reduction
97.5%
_y NSF testing.
Average Product
Water
Concentration
0.05 mg/L
At least 10,000 particles/mL
Minimum
50,000 cysts/L
107 to 108 fibers/L;
fibers
greater than 10 tJm in length
0.009 mg/L + 10%
0.015 mg/L + 10%+
0.08 mg/L + 10%
0.006 mg/L + 10%
0.15 mg/L + 10%
0.15 mg/L + 10%
0.002 mg/L + 10%
0.006 mg/L + 10%
0.006 mg/L + 10%
0.225 mg/L + 10%
0.015 mg/L + 10%
0.015 mg/L + 10%
0.210 mg/L _+10%
Max Permissible
Product Water
Concentration
N/A
NSFReduction
Requirements
->50%
Test Report
J-00077703
7,833,333
pts/mL
99.7%
18,617 pts/mL
N/A
>85%
J-00077704
101,000 cysts/L
99.99%
1 cyst/L
N/A
>99.95%
J-00100036
>99%
94.5%
96.7%
98.7%
97.1%
99.3%
99.3%
99.0%
93.2%
93.2%
99.8%
96.7%
93.2%
99.5%
N/A
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.002 mg/L
0.010 mg/L
0.010 mg/L
0.0002 mg/L
0.002 mg/L
0.002 mg/L
0.075 mg/L
0.005 mg/L
0.003 mg/L
0.07 mg/L
47 MF/L
0.009 mg/L
0.016 mg/L
0.08 rng/L
0.007 mg/L
0.152 mg/L
0.148 mg/L
0.002 mg/L
0.0058 mg/L
0.0061 mg/L
0.222 mg/L
0.015 mg/L
0.015 mg/L
0.218 mg/L
':Basedon the useof Cryptosporidium parvum oocysts.
>99%
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
<1 HF/L
0.0005 mg/L
0.0005 mg/L
0.001 mg/L
0.0002 mg/L
0.001 mg/L
0.001 mg/L
0.00002 mg/L
0.0004 mg/L
0.0004 mg/L
0.005 mg/L
0.0005 mg/L
0.001 mg/L
0.0009 mg/L
J-00077707
J-00077708
J-00077717
J-00077718
J-00100039
J-00077722
J-00077723
J-00077726
J-00100037
J-00092355
J-00077729
J-00082184
J-00077730
J-00085470
The following
pharmaceutical
reduction
claims have not been certified
by NSF International
or the state of California,
Claims
tested
and verified
by independent
laboratory:
I
I
Average Product
Contaminant
NSFspecified
Avg%
Water
Reduction
Average tnfluent
Challenge Concentration
Reduction
Concentration
978 ng/L
N/A
99.5%
5.0 ng/L
907 ng/I
N/A
99.4%
5.4 ng/L
885 ng/L
N/A
94.1%
52.3 ng/L
1097 ng/L
N/A
99.5%
5.0 ng/L
415 ng/L
N/A
99.5%
2.0 ng/L
Max Permissible
I
Product Water
NSF Reduction
Concentration
Requirements
Test Report
N/A
N/A
J-00121587
N/A
N/A
J-00121587
N/A
N/A
J-00121588
N/A
N/A
J-00121589
N/A
N/A
500121587
Application
GuidelinesANater
Supply
Parameters
Service Flow
0.5 gpm
(21.9 Ipm)
Water Pressure
40-120 Ds 2 8-8 2 bar
Water Supply
Potable
Water
Water Temperature
33°F-100°F (0.6°C-38°C)
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note:
While the testing was performed
under standard laboratory
conditions,
actual performance
may vary.
Replacement
Cartridge: MWR For estimated costs of replacement
elements
please call 1-800-626-2002
or visit our website at www.geapplianceparts.com.
Z_WARNING
To reduce the risk associated
with ingestion
of contaminants:
• Do not use with water that is microbiologically
unsafe or of unknown
quality
without
adequate
disinfection
before and after the system. Systems certified
for cyst reduction
may be used on disinfected water that may contain filterable
cysts. EPA Establishment
Number 10350-MN-005.
For conditions
of use, I'/ealth claims certified by the California Department
of Public
Health, and replacements,
see performance
data sheet. California Department
of Public Health Certification
#05-1698. The contaminants
or other substances
removed or reduced by this water filter are not necessarily in all users' water.
NOTICE
To reduce the risk associated
with property
damage
due to water
leakage:
• Read and follow use instructions
before installation
and use of this system.
• Installation
and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (8.2 bar). If your water pressure
exceeds 80 psi, you must install a pressure-limiting
valve. Contact a plumbing
professional
if you are uncertain
how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water Iqammer arrester. Contact a plumbing
professional
if you are uncertain
how to check for this condition.
• Do not install on hot water supply lines. The maximum
operating water
temperature
of this filter system is 100 ° F(38° C).
• Protect filter from freezing. Drain filter when temperatures
drop
below 33°F (0.6°C).
• The disposebte filter cartridge
must be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction
in flow rate occurs.
_
Tested and certified by NSFInternational
1,_1m-
£
r<_j
against NSF/ANSIStandard 42 and
Standard 53 in model GEMWF fur the
REPLACEMENT
_
reduction of the Uaims specified on the
ELEMENf
pertotmance
data