Terminal block table for Ref. 1093/184M14, Ref. 1093/184M15 and Ref. 1093/184M16
Connect alarm actuators (e.g. sirens) to DOUT and COM terminals
Connect alarm detectors to DIN and GND terminals
Short-circuit the default terminal with the ground terminal (GND) to reset default parameters and settings.
2.4.1
HOW TO ADJUST FOCUS
Ref.1093/184M11 and Ref.1093/184M12 models: turn the focus ring clockwise to obtain the required picture.
For Ref.1093/184M15 and Ref.1093/184M16 models: loosen the front dome and adjust focus and zoom using the two levers by
the side of the lens. After adjusting, fasten the levers to maintain the setting.
IMPORTANT NOTE:
Cameras Ref.1093/184M11 and Ref.1093/184M12 must be connected to the network before adjusting the focus. Cameras
Ref.1093/184M15 and Ref.1093/184M16 may also be connected directly to a monitor with analogue video input and BNC
connector.
2.4.2
MICRO-SD CARD
The camera is provided with a micro-SD card slot for local recording (see § 2.2, § 2.3 and § 2.4 of the manual to locate the
micro-SD card slot on your IP camera model). It is advisable to switch the camera off before inserting/removing the micro-SD
card into/from the slot.
IMPORTANT NOTE:
Disconnect the camera power to replace the micro-SD card.
This camera uses micro-SD/SDHC Class 6 cards from 4GB to 32GB.
CAMERA IP CONFIGURATIONS
3
The camera must be configured for the home or office network after it has been powered.
It is advisable to install and configure one camera at a time if you are installing multiple cameras on the same network.
3.1
CONNECTION TO IP NETWORK WITH DHCP SERVICE
No PC is needed to set up the camera with dynamic host configuration (DHCP) on the network (either Wi-Fi or wired). Simply
follow the appropriate workflow shown in the following charts according to the operating system of your smartphone: iOS
(version 7.1 or higher) or Android (version 4.0.x or higher with at least 4" display).
IMPORTANT NOTE
For more information on how to configure the camera using iOS/Android terminals, see the Urmet Cloud App Quick Start Guide
in the app itself or the complete Urmet Cloud App instruction manual on the CD provided with the product.
A PC must be used for static host configuration as shown in § 3.2 below.
DS1093-106A
1
Default = Hard reset terminal
2
GND = Ground terminal
3
GND = Ground terminal
4
DIN = Alarm input terminal
5
DOUT = Alarm output terminal
6
COM = Common terminal