2.10 Troubleshooting

Symptom
Flame effect does not start
The flame effect is too low.
Unpleasant smell during use
The flame effect gives off
too much smoke
The lights are not burning
and there is no smoke visible
Condensation on the glass.
Scale on the glass.
23 <
<
<
<
Cause
The plug is not in the wall
socket.
Switch "A" is in ´ON´
position, but switch "B" has
not been pressed.
Water level is low.
Plug on collection reservoir is
not connected properly
(See Fig.9)
The flame effect button "C"
is switched low (See Fig.2)
The water level in the
collection reservoir is too
high, because the drawer was
opened several times, the
water tank was removed
several times or the fireplace
was moved.
The metal discs in the
collection reservoir are dirty.
(See Fig.14)
Dirty or old water.
Unfiltered tap water has been
used.
The flame effect button "C"
is too high
Water tank is empty
Appliance has not been
connected properly
Appliance is switched off.
The glass surface is cold.
Unfiltered water was used
Solution
Put the plug in the wall socket.
Press switch "B".(See Fig.2)
When the switch is ´ON´
Fill water tank.
Check the connection within the appliance (See Fig.9)
Turn the flame effect button "C" up. (See chapter 2.5.2)
When the water level in the collection reservoir is higher
than 40mm, the reservoir should be emptied in the sink.
Clean the metal discs with the supplied brush.
(See chapter 2.9.2)
Clean the unit as described in chapter 2.9
Only use filtered tap water.
Turn the flame effect button "C" down (See chapter 2.5.2)
Turn slowly until the desired effect has been reached. Turn
the button a quarter to the right, and give the smoke
generator some time to adjust.
Fill the water tank (See chapter 2.8.2).
ensure that the plug is inserted in the wall socket properly
Put switch "A" in the "ON" position and/or
press switch "B" once until one beep can be heard.
Turn the flame effect down during this process.
Use filtered water.