2.2

Scope of delivery

U
max
I
I
min
20 pcs. wire end ferrules
The B-1993x motor-driven shoot-bolt lock can be operated with a nominal current of 2A-4.2A.
The amount of operating current depends on the loads exerted on the door leaf.
If only low loads are anticipated due to gasket sealing forces, wind load, draught, etc., a correspon-
ding power supply unit with low output can be used. A power supply unit with a higher output is
therefore especially recommended at external doors and in staircases.
The diagram below can be used as a decision-making aid. The green area represents the operating
range of the motor-driven shoot-bolt lock.
2.3

Accessories

+
Controller incl.
service plug
B-54900-01-4-9
10 m
2
LiYY 14 x 0,14 mm
(Ø ~ 6,5 mm)
14-pin connection cable
B 5490 0300
24 V DC +25 % / -15 %
2 A - 4,2 A
100 mA
P
100 W
max
U
100-240 V AC
in
24 V DC ± 1 %
U
out
I
4.2 A
max
Power supply
unit
B 5570 0401
2 m
EN 61386-22 M16
(Ø ~ 16 mm)
Cable protection hose
B 5490 0308
F [N]
Dimensions (WxHxD):
24 x 480 x 17/
24 x 300 x 3
U
24 V DC
max
I
4 A
max
Detachable door loop
B 5527 0004
Service plug
(replacement)
B 5528 0931