1.3

Installation notes:

y
y
Make sure the lock recess is free of swarf. Remove swarfes thoroughly from lock recess and door
profile, before mounting the locks.
y
y
Protect the connection cable against abrasion.
We recommend to use the B 5490 0308 cable protection hose (separately available).
y
y
Pull the swarf guard onto the connection cable. Then fully insert the plug of the connection cable
into the socket. Pull the swarf guard over the plastic connecting clip (see Fig.).
y
y
Create a cord grip using a cable tie on the plastic connecting clip (see Fig.).
y
y
Mount the lock and the vertical rods in the door. As you do so, arrange the connection cable such
that a sufficiently large cable loop remains.
Make sure that the connection cable is not buckled or in tension and the upper B 9006 tube with
end plug runs without friction!
The copper-coloured transport securing devices on the triggers should remain in place until the
door system is installed in its final location.
y
y
Connect the power supply and connection cable to the control unit B-54900-01-4-9,
as shown here.
y
y
Open both door leaves and make sure they cannot be closed accidentally.
y
y
Make sure that the programming plug is inserted into the control unit.
y
y
Then trigger a test run via a control pulse at input I2. The motor-driven shoot-bolt lock slowly
performs a complete work cycle (releasing, locking).
When making changes to or replacing individual components (controller B-54900-01-4-9,
motor-driven shoot-bolt lock B-1993x or connection cable B 5490 0300 / 0308), you must repeat
the test run (see point 6.5)!