OBJ_BUCH-3470-001.book Page 10 Wednesday, December 13, 2017 9:42 AM
10 | English
Mounting and Operation
Action
Product features
Delivery scope
Charging the battery pack
Connect/disconnect the cleaning head D
Filling the spray applicator
Connecting the spray applicator head
Attaching the microfiber cloth 110 mm F
Connect the applicator head 276 mm
Attaching the microfiber cloth 276 mm
Disconnect spray applicator head
Using
Empty the dirty water tank
Cleaning the machine
Detach the microfiber cloth 110 mm
Cleaning microfiber cloth
Accessories
Initial Operation
Observe the mains voltage! The voltage of the power
source must correspond with the data on the type plate of
the battery charger.
Troubleshooting
Problem
Possible Cause
Machine will not switch on
Battery discharged
Battery too hot/cold
Restricted or no vacuum
Cleaning head blocke
Drain plug remove
Machine turns itself off
Battery too hot/cold
Cleaning head blocke
Water leaks from machine
Spray applicator not mounted correctly
Battery will not charge
Charger not connected correctly
Battery too hot/cold
Streaking on windows
Wiper blade damagedt
Too much force appliedn
Too little force appliedn
Maintenance and Cleaning
(see figure J – K)
Always clean the product thoroughly after use.
Remove the cleaning head from the main body and rinse.
Whilst cleaning head 2 is removed from the machine, fill the
dirty water tank 7 via the cleaning head aperture to the max
line with clean, warm water. DO NOT fill the dirty water tank 7
F 016 L81 778 | (13.12.17)
Note: The battery supplied is partially charged. To ensure full
capacity of the battery, completely charge the battery using
the charger before using your machine for the first time.
Figure Page
The lithium-ion battery can be charged at any time without re-
A
147
ducing its service life. Interrupting the charging procedure
B
148
does not damage the battery.
C
149
The battery is protected against deep discharging.
149
When the battery is discharged, the machine will stop.
E
150
Battery Charging (see figures A and C)
Note: The micro-USB port 20 for connection of the micro-
150
USB cable 17 is in the handle.
G
151
When the battery charge is low, the charger level indicator 4
flashes green.
When the charger level indicator 4 flashes red the battery
H–I
152–154
must be charged. Turn machine off and charge the battery.
I
154
Connect the machine to the charger 18 using the micro USB
J–K
154–155
cable 17 provided. Plug the charger 18 into the socket. The
charging process begins.
L
156
During the charging procedure, the handle of the machine
warms up. This is normal.
M
156
The charger level indicator 4 continuously lights up red during
the charging procedure. When the battery is fully charged, the
charger level indicator 4 continuously lights up green.
Disconnect the charger from the mains supply when charging
process ends.
Observe the notes for disposal.
via the drain hole. Shake the machine and pour the water out
via the drain plug 8.
Maintenance of the cleaning head
Protect the cleaning heads against damage during storage.
Prevent the wiper blade from touching paper or cardboard, as
this could damage the wiper blades polymer coating.
Spots or lines may be visible on the polymer coating. This is
normal and does not affect the cleaning performance.
Corrective Action
Recharge battery
Allow to cool/warm
Unblock cleaning head
Replace drain plug
Allow to cool/warm
Unblock cleaning head
Mount the spray applicator correctly
Check charger and USB cable connections
Allow to cool/warm
Replace wiper blade (accessory)
Apply reduced force
Apply more force
Bosch Power Tools