The appliances in this series offer the
possibility of working either as hot or cold air
curtains.
Please check that the appliance is in perfect
state when you unpack it, as any
manufacturing defect is covered by the S&P
guarantee.
IMPORTANT INSTRUCTIONS
SAFETY WARNINGS
This appliance should not be located directly
below or above an electrical power point.
Do not cover it with objects or garments that
could impede the free circulation of air.
Covering the unit may cause it to overheat.
While in operation, the power cable should not
be in front of the air outlet.
If installed in a bathroom, it should be fitted in
such a manner that the switches or other
controls cannot be touched by a person while
in the bath or shower.
All inflammable objects should be kept at least
50 cm away from the hot air circuit (curtains,
etc.).
Keep the air inlet and outlet grilles clean.
Before cleaning the appliance or manipulating
anything inside it, make sure it is disconnected
from the mains supply.
Do not manipulate the appliance with wet
hands.
This unit should be installed by an electrician.
IMPORTANT:
T H E S E U N I T S M U S T A LWAY S B E
EARTHED.
The disconnection device to be incorporated
to the wiring system for cutting the mains
power supply of both poles should have at
least 3 mm clearance between the contacts of
the poles.
For operation as an air curtain, the distance
from the floor should be no greater than 4
metres.
The minimum distance between the curtain
and the floor should be 2.5 metres.
INSTALLATION
The unit must be secured to an appropriate
surface for this application.
Observe the minimum distances as indicated
in Fig.1.
This is the process for installation:
First, choose the fitting option, according to the
type of ceiling and space available: LOWER
FASTENING OPTION
FASTENING OPTION (Fig. 4B). Then fit the
threaded rods (or Rawplugs with their nuts,
following the dimensions indicated in the
illustration on Figs. 2 and 3.
Next, fit the curtain, making sure it is level with
the plates of the false ceiling, so that when the
grille is fitted with the bolts (A) Fig. 5, it will fit to
the ceiling.
The working pressure of the water radiator
must not exceed 4Kg/cm2.
The hot water temperature must not exceed
95°C.
The water battery must not work at
temperatures below 5°C. If it is thought that the
temperature could descend below this limit,
either antifreeze liquid should be used or the
installation should be emptied.
The water pump should be connected to the
battery using the 1/2" gas thread inlets on the
unit.
ELECTRICAL WIRING (Fig. 6)
These units are for fixed installation. When
connecting to the mains, apply the guidelines
indicated in the
Low Voltage Regulations as well as any
applicable national regulations.
The installation should have a circuit breaker
or some other type of device for complete
disconnection of the power supply to the unit.
Before connecting to the mains supply, check
that its voltage is the same as that indicated on
the specifications plate of the unit.
Use cable with a section and number of wires
as indicated in the diagrams corresponding to
each model.
Secure the cables with glands.