Control Leds - Genius JA510C Instrucciones Para El Uso

Control board for rolling gates
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
3.3.2 Start - Opening and closing
Terminals "8-10" (Circuit Normally Open). The status of this input is displayed by LED 2. This circuit is
connected to any device (e.g. button, radio control, etc.) which, when a contact is closed, generates
a rolling gate opening and/or closing pulse.
Note: To install multiple pulse generators, connect the contacts in parallel.
3.3.3 Closing protection photocells
Terminals"11-12" (Circuit Normally Closed). The status of this input is displayed by LED 3. This circuit is
connected to any safety device (photocells, pressure switch, detector, etc.) which, when a contact is
opened, acts as a safety on the closing motion. The effect will differ depending on the programming
set using dip-sw 4.
Note: If safety devices are not connected, jump connect the input. To install multiple safety devices,
connect the NC contacts in series.
3.3.4 Accessory power supply
Terminals "13-14" (24 Vdc). WARNING: the max. load on the accessories is 500 mA.
4. INSERTING THE REMOTE CONTROL RECEIVER BOARD
The control unit is designed to house a one-channel radio receiver module. To install, cut off the electric
power supply and insert the module into the special connector M3 inside the control unit. Then follow
the radio receiver instructions to store the remote control value.
LEDS
1 - Stop
2 - Start
3 - Photocells
Note: Bold is used to indicate the condition of the LEDS with the rolling gate at rest.
OPERATING LOGIC
Step step
Automatic
CLOSING PHOTOCELL OPERATION
Blocks and reverses the motion
Blocks and when disabled, restarts
Note: all adjustments must be performed with the control unit turned off and the rolling gate closed.

5. CONTROL LEDS

ON
Control deactivated
Control activated
Safety devices disabled
6. DIP-SWITCH ADJUSTMENTS (SW1)
Pause time (sec.)
5
10
15
20
30
45
60
6
OFF
Control activated
Control deactivated
Safety devices enabled
1
2
3
OFF
OFF
OFF
ON
OFF
OFF
OFF
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
4
OFF
ON
Tabla de contenido
loading

Tabla de contenido