Filter Replacement; Cleaning & Maintenance; Troubleshooting Guide - Guardian Technologies AC9400 Serie Instrucciones De Utilizacion

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

RESETTING THE AIR PURIFIER
The air purifier is equipped with a motor protection circut. If activated, the overload warning indicator
will initiate and cut off the power. An audible warning "chime" will sound for 60 seconds along with a
flashing error "Err" warning on the display. To restart the unit, unplug the unit for 10 minutes, then
plug back in and power on.
Note: If the unit continues to shut down, there may still be an abnormal condition and the unit
may need service.

FILTER REPLACEMENT

The Replace Filter Indicator light will flash when it is time to replace the filter. Depending on usage
and environmental conditions the filter will last approximately 6 months. The filter will be covered in
dust when it is dirty and needs replacing. It is important to maintain and change the filter to continue
to optimize the performance of the purifier.
IMPORTANT: DO NOT wash and re-use the filter. Please contact Customer Service to purchase a
replacement filter. Use only Genuine Guardian Technologies Replacement Parts to optimize the
performance of your air purifier.
1. Turn off and unplug the unit.
2. Remove the front panel by pulling cover from sides and lift panel from base.
3. Unlock filter by rotating lever to the left.
4. Replace with new filter. Closed end of filter should be on the bottom. Open end on top.
5. Lock filter by rotating lever to the right.
6. Return the front panel. First insert the front panel bottom hooks then close.
NOTE: Make sure front panel is closed properly.
REPLACEMENT FILTER
FILTER:
K
Filter
Model No. FLT9400
CLEANING & MAINTENANCE
CLEANING
Always unplug the appliance before you clean it. Never immerse the appliance in water or any
other liquid. Never use aggressive or flammable cleaning agents such as bleach or alcohol to
clean any part of the appliance.
BODY OF THE APPLIANCE
Regularly clean the inside and outside of the body to prevent dust from collecting on the
inside and outside.
1. Wipe away dust with a soft dry cloth from the body of the appliance.
2. Clean the air inlet and the air outlet with a soft dry cloth.
PRE-FILTER SCREEN
The pre-filter is designed to collect larger dust and debris and should be cleaned monthly or more
frequently depending on use. Clean regularly with the brush attachement or your vacuum cleaner.
This will remove the lint and dirt and help maintain the life of the filter (see filter replacement to
locate and remove filter).
E-6
Unit will not function when panel is open.
Check out our
Filter Replacement Program
www.guardiantechnologies.com
IMPORTANT: Use Guardian Technologies GENUINE
Replacement Parts only. Contact Customer Support
or visit our website www.guardiantechnologies.com.
NOTE: Do NOT stick any foreign objects or your fingers inside of the unit.
CAUTION: Do NOT use gasoline, benzene, thinner, harsh cleaners, etc. on and/or in the
unit while cleaning as they will damage the product.
NEVER use alcohol or other solvents
What is CADR?
CADR stands for "Clean Air Delivery Rate," which indicates the volume of filtered air delivered by an
air purifier. CADR ratings show the effectiveness of how efficient the air purifier is at capturing fine
particles from things like tobacco smoke and plant pollens from the room.
Clean Air Delivery Rate
From air cleaner to air cleaner, compare the CADR numbers. First look at suggested room size.
Then refer to the Clean Air Delivery Rate (CADR) numbers. The higher the number, the faster the
unit filters the air.
Refer to website for individual model CADR numbers.

TROUBLESHOOTING GUIDE

PROBLEM
SOLUTION
Unit shuts off unexpectedly
Check that the unit is plugged into a working electrical outlet.
or does not operate.
Check that the motor protector is triggered.
Check that the filter is in the unit and locked.
Check that the front panel is latched firmly in place.
No air circulating from unit.
Unplug unit. Check filter. Replace filter if necessary.
Increase in noise level.
Make sure the filter is clean. Replace if necessary.
Odors and smoke are
Clean or replace the filter if it appears to be heavily soiled.
not removed.
The discharged air has an
Check to see if the filter is heavily soiled. Replace the filter.
aroma or odor.
Turn off the Ionizer.
E-7
Tabla de contenido
loading

Tabla de contenido