IMPORTANT REMARKS

For any installation problems please contact
V2 ELETTRONICA TEL. (+39) 01 72 81 24 11
V2 ELETTRONICA has the right to modify the product without
previous notice; it also declines any responsibility to damage
or injury to people or things caused by improper use or wrong
installation.
Please read this instruction manual very carefully before
installing and programming your City1 control unit.
• This instruction manual is only for qualified technicians,
who specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service
should be done only by qualified technicians.
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply.
The standards require a separation of the contacts
of at least 3 mm in each pole (EN 60335-1).
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of
accidental detachment of a conducting wire, dangerous
voltage parts will not come into contact with safety low
voltage ones.
• The plastic case has an IP55 insulation; to connect flexible
or rigid pipes, use pipefittings having the same insulation
level.
• Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (EEC Machine Directive 89/392, Annex IIA).
• Also the automation upstream electric system shall comply
with the laws and rules in force and be carried out
workmanlike.

CONFORMITY TO REGULATIONS

V2 ELETTRONICA SPA declares that City5 is in conformity with
the provisions of the followings 93/68/EEC, 73/23/EEC, and
with the standards referenced here below:
EN 60335-1
EN 55014-1, EN 55014-2
EN 61000-3-2, 61000-3-3
Racconigi, 10/02/2004
V2 ELETTRONICA SPA legal representative.
A.Livio Costamagna
Electrical safety
Electromagnetic compatibility

TECHNICAL SPECIFICATIONS

Power supply
Feedeing of the lamps of
the light
Max. charge of the lamps
of the light
Max accessories load 24V 3W
Working temperature
Protection fuse
Dimensions
Weight
Protection
20
230VAC - 50/60 Hz (City5)
120VAC - 50/60Hz (City5-120V)
Direct or alternating current,
max 250VAC
5A
-20°C / +60°C
F1 = 400mA / F2 = 5A (City5)
F1 = 800mA / F2 = 5A (City5-120V)
195 x 145 x 80
800 g
IP55