Sima CX-16 Manual De Instrucciones página 69

Ocultar thumbs Ver también para CX-16:
Idiomas disponibles
  • ES

Idiomas disponibles

●Make sure to take off the battery pack from tools before checking the tools.
■For long life use.
Keep clean the tool after use.
Do not use thinner or benzene on the plastic parts to avoid color-change.
Keep apart from the place of direct sun light, high temperature, high humility
and dust.
Also, keep it away from the children.
Long custody (More than 1 year) may have the battery discharge or inactivate
chemical material.
You need to keep it on dry and low temperatures place. (+10℃~+25℃)
Recharging and discharging are required in case of no use more than 6 month.
■Replenishing and replacing hydraulic oil
Tools need more hydraulic oil if performance gets down.
No enough hydraulic oil causes the damage and defects of tools.
Hydraulic oil: hydraulic oil ISO VG46 is preferable. e.g. Shell Oil Tellus 46, Mobil
oil DTE-25 or Esso Uni power SQ46
Fill in with oil when the cutter rod
and hold rebar (D10) by rod (with pressure), otherwise, oil spill out.
Pay careful attention not to insert foreign matter or dust into the oil.
It may cause the trouble if dust get enter inside.
■Trouble-shooting
If you have trouble with the apparatus, or have question, please contact our
shop or distributors nearby.
■Battery pack is recyclable.
The battery is precise resources, when you damp it, please bring it to our
agents or shops for recycling.
In case you take off the oil,
is fully expanded.
9
loading

Este manual también es adecuado para:

Cx-20Cx-25