Promax GV-198 Manual De Instrucciones página 32

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

No. of lines / field
Frame frequency
Line frequency
Horizontal synchronism
Line period (1/f
H
Previous pedestal
Synchronism
Blanking
Vertical synchronism
Frame period
Blanking
Pulse time of:
Pre-equalizing
Equalizing
Post-equalizing
PAL colour subcarrier
Frequency (B, G, H, D, K, I)
Frequency (N)
Frequency (M)
Burst duration
Burst position
Phase
Amplitude Error
Burst
Chrominance
NTSC colour subcarrier (M)
Frequency (M)
Burst duration
Burst position
Phase
Amplitude Error
Burst
Chrominance
SECAM colour subcarrier (B, G, H, D, K, L)
Subcarrier frequency
Line identification points
Page 2
625
50 Hz.
15625 Hz.
64 µs ± 100 ns
)
1.6 µs ± 100 ns
4.8 µs ± 100 ns
12 µs ± 100 ns
20 ms ± 100 ns
(H=64 µs)
25 H + 12 µs
2.5 H
2.5 H
2.5 H
4.43361875 MHz <± 30 ppm (10 °C to 40 °C)
3.58205625 MHz <± 30 ppm (10 °C to 40 °C)
3.5756118 MHz <± 30 ppm (10 °C to 40 °C)
2.4 µs (10 ± 1 Fsc period)
5.6 µs + 100 ns from the line previous
synchronism flank.
135° as referred to U axis
± 5%
ON / OFF, selectable
ON / OFF, selectable
3.579545 MHz <± 30 ppm (10 °C to 40 °C)
2.38 µs (10 ± 1 Fsc period)
5.56 µs + 100 ns from the line previous
synchronism flank.
-180° as referred to U axis
± 5%
ON / OFF, selectable
ON / OFF, selectable
Fdr = 4.406250 MHz ± 2 kHz
Fdb = 4.250000 MHz ± 2 kHz
Selectable ON / OFF using burst key
TV generator GV-198
525
60 Hz.
15734 Hz.
63.56 µs ± 100 ns
1.59 µs ± 100 ns
4.77 µs ± 100 ns
11.12 µs ± 100 ns
16.68 ms ± 100 ns
(H=63.56 µs)
21 H + 11.12 µs
3 H
3 H
3 H
01/2004
Tabla de contenido
loading

Tabla de contenido