Drawing 14
The maximum length for all pipes channeling air is of 14 meters. If the user needs longer pipes, he/she must
install an additional ventilation motor (see the diagram detailing the different parts.
ON-OFF Pushbutton.
Thermostat connection.
Power connection ~230/240V - 50Hz.
USB platform for wi-fi adaptor.
Wi-fi adaptor.
The location of the ON-OFF pushbutton varies depending on the stove model:
Venecia: Side door to the left.
Ibiza: Side door to the right.
Kiev: On top of the power and room sensor connections.
Kiev Insert: Behind the hopper lid and on top of the safety thermostat
Oslo: On top of the power and room sensor connections.
Oslo insert: Between the grid to the right and the frame.
Section 5 of the user manual is devoted to the use and functions of this pushbutton.
IF YOU HAVE ANY DOUBT ABOUT THE CONNECTION, THE INSTALLATION PRACTICABILITY OR THE USE OF
SUCH DEVICES, CONTACT YOUR DISTRIBUTOR WHO WILL INFORM YOU.
A BAD USE OR SETTING OF THESE DEVICES MAY CAUSE A MALFUNCTION OR EARLY DEGRADATION OF THE
STOVE.
Drawing 15
OSLO MODEL.
POWER CABLE AND ROOM THERMOSTAT.
LOCATION OF THE ON/OFF PUSHBUTTON.
33
Drawing 16
Drawing 17