• Make sure that the power cable doesn't touch the hottest parts
of the device.
• Don't use the device to dry clothes or towels.
• Device designed for interior use.
2. INSTALLATION
Before installing the device, read all the Safety Warnings indicated in the above section
carefully.
1. This device can be installed with the control box on the right side (Fig. 1 A) or on the left
side (Fig. 1 B). The device is pre-assembled in the factory to be installed with the control
box on the right (Fig. 1 A).
If, due to the layout of the washroom you have to install the device with the control box on
the left side (Fig. 1 B), proceed as follows:
− Remove the front cover with a screwdriver, pressing on the two tabs on the side of the
device (See Fig. 4).
− Change the route of the cord that operates the rotary switch, so that it comes out
through the groove on the other side.
NB: Once installed, the cord must always come out through the groove on the bottom of
the control box.
2. To increase the sensation of heat from the device, you can orient the head so that it pro-
jects the heat more directly towards the fl oor, in the desired area. The angle of rotation is
approximately 30º (See Fig. 3).
The head's orientation will depend on the installation layout.
− If you have an installation layout with the control box on the right side (Fig. 1 A) and you
want to orient the head by tilting it towards the fl oor, you must previously remove screw
A inside the control box (See Fig. 7A).
− If you have an installation layout with the control box on the left side (Fig. 1 B) and you
want to turn the head, tilting it towards the fl oor, you must previously remove screw B
inside the control box (See Fig. 7B).
NB: One of the two screws indicated (Figure 7A-7B) must always stay put, never remove
both screws.
3. ELECTRICAL CONNECTION AND FIXTURE
NB: Before connecting the device, check that its electricity supply is completely disconnected
and read all the Safety Warnings indicated in the corresponding section carefully.
Note: The device comes with a rotary single-pole switch, providing a distance ≥3mm between
contacts.
• Remove the front cover with a screwdriver, pressing on the two tabs on the side of the
device (See Fig. 4).