Option Parts List

Model
SG Link Set
E Tip Wrench
VS Tip Wrench
19

Spare Parts List

Model
LED handpiece with Cord
Irrigation Tube
Tube Holder
Tip Holder
Tip Wrench
20

Disposal of the product

In order to avoid the health risks of operators handling the disposal of medical equipment, as well as the risks of
environmental contamination caused thereof, a surgeon or a dentist is required to confirm the equipment is sterile. Ask
specialist firms who are licensed to dispose of specially controlled industrial wastes, to dispose the product for you.
21

EMC Information (Electromagnetic Compatibility Information)

Guidance and manufacturer's declaration - Electromagnetic Emissions
The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment.
Emissions test
RF emissions
CISPR11/EN55011
RF emissions
CISPR11/EN55011
Harmonic emissions
EN/IEC61000-3-2
Voltage fluctuations/flicker emissions
EN/IEC61000-3-3
Guidance and manufacturer's declaration - Electromagnetic Immunity
The product is intended for use in the electromagnetic environment specified below. The customer or the user of the product should assure that it is used in such an environment.
Immunity test
EN/IEC60601 test level
Electrostatic discharge (ESD)
±(2, 4) 6kV contact
EN/IEC61000-4-2
±(2, 4) 8kV air
Electrical fast transient/burst
±2kV for power supply lines
EN/IEC61000-4-4
±1kV for input/output lines
Surge
±1kV line(s) to line(s)
EN/IEC61000-4-5
±2kV line(s) to earth
Voltage dips, short
<5% Ut
interruptions and voltage
(>95% dip in Ut)
variations on power supply
for 0.5 cycles
input lines
40% Ut
EN/IEC61000-4-11
(60% dip in Ut)
for 5 cycles
70% Ut
(30% dip in Ut)
for 0.5 cycles
<5% Ut
(<95% dip in Ut)
for 5 sec
Power frequency (50/60Hz)
3 A/m
magnetic field
EN/IEC61000-4-8
NOTE: 'Ut' is the AC mains voltage prior to application of the test level.
Order Code
Y1002729
Z217399
Z305350
Order Code
E1133001
Y900113
Y900767
20001327
10000977
Compliance
Electromagnetic environment - guidance
Group 1
The product uses RF energy only for its internal function. Therefore, its RF emissions are very low and
are not likely to cause any interference in nearby electronic equipment.
Class B
The product is suitable for use in all establishments, including domestic establishments and those
directly connected to the public low-voltage power supply network that supplies buildings used for
domestic purposes.
Classe A (except 120V)
Complies (except 120V)
Compliance level
±(2, 4) 6kV contact
±(2, 4) 8kV air
±2kV for power supply lines
±1kV for input/output lines
±1kV line(s) to line(s)
±2kV line(s) to earth
<5% Ut
(>95% dip in Ut)
for 0.5 cycles
40% Ut
(60% dip in Ut)
for 5 cycles
70% Ut
(30% dip in Ut)
for 0.5 cycles
<5% Ut
(<95% dip in Ut)
for 5 sec
3 A/m
Remarks
For V10-S
Remarks
5 pcs
7 pcs
Electromagnetic environment - guidance
Floors should be wood, concrete or ceramic tile. If floors are
covered with synthetic material, the relative humidity should be
at least 30%.
Mains power quality should be that of a typical commercial or
hospital environment.
Mains power quality should be that of a typical commercial or
hospital environment.
Mains power quality should be that of a typical commercial or
hospital environment. If the user of the product requires
continued operation during power mains interruptions, it is
recommended that the product be powered from an
uninterruptible power supply or a battery.
Power frequency magnetic fields should be at levels
characteristic of a typical location in a typical commercial or
hospital environment.