This documentation is part of the information delivered with the
appliance and must be given to the user and stored in a safe place.
The product must be installed and serviced by trained engineers, in
compliance with current standards.
ACV shall not accept any responsibility for damage caused by
noncompliant location of the system or by use of the parts or
connections not approved by ACV for this application.
Any failure to follow instructions relating to tests and test
procedures may result in personal injury.
1. INTRODUCTION
These instructions should be read by the specifying engineer, the installer,
the user and the service engineer.
ACV reserves the right to change the technical specifications and
components of its products without prior notice.
2. INSTALLATION
The installation must comply with the instructions in this manual and
with the codes and standards governing systems for the production of
hot water.
The tank must be installed in the vertical position only, floor standing in
a dry room.
The pipe feeding the tank with cold water must be fitted with a safety
unit comprising at least the following:
- an isolating valve.
- a non-return valve.
- a safety valve (set to < 10 bar)
- a sanitary expansion vessel of appropriate dimensions.
When the operating pressure exceeds 6 bars a pressure reducer must
be installed before the safety unit.
To avoid water leakages on the tank, the safety valve should not be
located on top of the tank.
There is a risk of scalding from hot water! ACV recommends the use of
a thermostatic mixing valve set to provide water at 60 °C or less.
Typical domestic water connection (fig.A):
Mount the provided stopper if no heating element is mounted on the
tank. Check the watertightness.
Electrical connection: ensure the grounding connection meets the
applicable regulations.
EN

3. GENERAL DESCRIPTION

1
Domestic cold water inlet.
2
DHW recirculation loop.
3
Inlet primary circuit.
4
Outlet primary circuit (partial load).
5
Outlet primary circuit.
6
Drywell.
7
Coil inlet.
8
Coil outlet.
9
Inlet low temperature primary circuit.
10 Outlet low temperature primary circuit.
11 Air vent, manual.
12 Domestic hot water outlet.
13 Rigid polypropylene top cover.
14 Shock-proof thick polypropylene outer casing.
15 Stainless steel inner tank, corrugated.
16 50 mm polyurethane insulation.
17 Drywell, stainless steel, with thermostat.
18 Outer tank, steel.
19 Heating element (optional).
20 Stainless steel coil.
21 Rigid polypropylene base.