Mains Input Voltage (J3 – AC)
Current consumption at 230V~
Main board supply voltage

2. Power Supply Specifications

Power supply voltage
Power supply current
Auxiliary Power output (J1)
Battery Power output (J3 – BAT)
Battery Type and max. capacity
Main board consumption
3. General Feature Specifications
End of line resistor (standard)
Standard on board output
Dimensions metal housing LxWxH
Environmental
4. Fuses
F1
Auxiliary power & siren
Mains fuse *
* Mains Fuse is part of the mains terminal block.
!
WARNING! Before removing the mains fuse, mains power must be disconnected (see page 4)!
1
The specifications depend on the battery capacity. The above table gives BS131 as an example.
ATS1201 Installation Guide
T
ECHNICAL SPECIFICATIONS
230 VAC ± 10% - 50Hz ± 10%
225 mA
23 VAC typical
13.8 VDC ± 5%
1.8 A max. at 13.8 VDC ± 5%
13.8 VDC ±5% 475 mA max.
Note: maximum permanent current to power devices external to the control
equipment in the absence of alarm conditions.
13.8 VDC ± 5% 1225 mA max. (BS131)
lead acid rechargeable
65 mA at 13.8 VDC ± 5%
4.7 kΩ 5% 0.25 W (2.2 kΩ or 10 kΩ)
Ext.siren (J7 - S+/S-)
360x260x82 mm
Operating temperature
Humidity
IP protection grade
F1 A, 20x5
F630 mA, 20x5
1
18 Ah 12 V nom. (BS131)
Electronic output
Colour
0° to + 50 °C (certified +5° +40°C)
95% non condensing
IP30
F2
Battery
1
Rating: 1 A at 13.8 VDC
Beige
F3 A, 20x5
7