4.
Installation of ATS 1201 (see
(1)
Earth connection. Use also for cable screen and
lid of box.
(2)
Processor
(3)
Mains power connection
(4)
Back-up battery
(5)
Pry-off tamper mounting location
To conform with CEI 79-2 regulations at level 2,
the use of the pry-off tamper is mandatory
(ST580 or ST590 kit). Note: The pry-off tamper
is not included with the product.
For detailed information on the PCB, see
connection diagram.
5.
Cabling ATS1201 with control
panel ATS2/3/4/4500
(Preferred System databus wiring - see
(Refer to the ATS Control Panel installation guide for a
more detailed description of the cabling)
The "TERM" link is on the first and last devices on the
system databus. In a "star" wiring configuration, the
"TERM" link is only fitted on the devices at the ends of
the two longest system databus cable runs.
(1)
TERM link fitted (first device on local databus)
(2)
Control Panel ATS2000/3000/4000/4500
(3)
ATS1105 LCD RAS (TERM switch not set to
ON)
(4)
Separate 12 V power supply. (Required if RAS is
more than 100 m from the nearest panel or
DGP. Connect "-" to "-" of the databus.)
(5)
Preferred data cable type is WCAT 52 (2 pair
twisted).
(6)
TERM link fitted (last device on local databus)
(7)
Earth connection to connect shield*
(8)
Any data gathering panel like ATS1201,
ATS1210, ATS1220 or ATS1250.
*Connect cable shield to one device only.
See: System databus connection and Earthing details
on page 5 and 6.
6.
Connection diagram ATS1201
(see
)
(1)
AC connection from transformer
(2)
System earth (see details page 6)
(3)
12 V battery
(4)
Earth connection for cable screens
(5)
Auxiliary power supply output
(6)
System databus
(7)
Normally closed front panel tamper contact
(8)
Normally closed rear panel tamper contact
(9)
Normally closed Alarm Contact
(10)
Normally Closed Tamper Contact
(11)
Interface to ATS1202 input expanders
(12)
External 8 Ohm siren speaker or siren
ATS1201 Installation Guide
(13)
)
(14)
(15)
(16)
J1
J2
J3
J4/J6
J5
J7
J8/J9
)
7.
TERM
TST 3
+12V
8.
Address
A
B
C, D
9.
Tx
Rx
10. System databus connection
The system databus is used to connect Data Gathering
Panels (to provide extra zones) and Arming Stations to
the ATS control panel. Remote devices can be up to 1.5
km from an ATS control panels.
Arming stations and Data Gathering Panels must be
connected via a 2 pair twisted shielded data cable from
the system databus connection. (WCAT 52 is
recommended)
The shield of the data cable should be connected to
earth at the ATS control panel and should be left
disconnected at any other end.
1K resistor must be fitted if external siren not
connected
Clock-out Interface to plug on output expansion
or 4-way non-clocked
Dipswitch to set DGP Address
Dipswitch to set options
Auxiliary power output.
RS485 system databus & box tamper
connections.
AC connection from transformer and
battery power
Zones
Interface to ATS1202 input expanders
External siren (S+/S-) and zones
Clock-out Interface to plug on output
expansion or 4-way non-clocked.
Links
Termination of databus. Only to be used
on first and last device on the local
databus.
Disable mains fail monitoring.
Connect +12VDC to output board
DGP dipswitch settings (see
Select DGP address. Set switches 1 - 4
to OFF to disable the DGP. (See fig. 2 for
correct address settings.)
Set to ON when 2 or 3 ATS1202 zone
expanders are connected to J5. Else set
to OFF.
Set to ON when a ATS1811 (8-way relay
card) or ATS1820 (16-way open collector
card) is connected to J8. Else set to OFF.
Not used. Set to OFF.
LEDs
Red LED flashes when panel is polling
remote unit(s). It must always be active.
Yellow LED flashes when remote units
(RAS and DGP) are replying to polling.
)
5