TROUBLESHOOTING, CAUSES, SOLUTIONS

TROUBLESHOOTING

No gas output
The product does not switch on
Thermal LED turned on
Power supply issue LED is on
HF does not work
LED communication
EXAGON turned off
Remote control
does not function
ASSEMBLY OF THE EXATIG COMMAND CABLE KIT
Assembly kit is supplied with command cable and two connectors to assembly (one male and one female connector)
In order to assembly control harness respect following steps:
1- Cut the protection at each cable endpoints
2- Fit the connector insulation material
3- Strip the endpoints of 10 wires on 5 mm
4- Repeat the operation with second connector at the other cable end
5- Connect wires according the diagram below:
(wire withe transparent plastic)
6 - Screw and tighten 2 rings on the connector.
7 - Turn the cable with a 1/4 turn and put inside in order to prevent the plate from blocking the wires for the next step.
8 - Screw and tighten the 2 screws holding the cable on each insulation sheet (ground without block out).
24
Closed bottle
Flowmeter closed
Defective trigger control
Turned off generator
Polarity default
The generator voltage level is too low <10V
Product is used out of its specifications
The product has been overcharged
Lift mode selected
Non conducting workpiece
Earth default
Defective trigger control
EXAGON is off
Connection lead between the two products is not plugged.
Interconnect cable fault
The connection of EXATIG with EXAGON is preventing the remote
control from functioning.
Command cable
(21544)
Wire diameter
Wire 0.75
Wire 0.50
EXATIG HF
CAUSES
(réf. 036918)
B
D
H
Wire colour
Yellow
Green
Brown
White
Yellow
Brown
Green
White
SOLUTIONS
Open the bottle
Unscrew the knob
Replace the torch
Turn on the generator to supply EXATIG
Check back the connection (page 2)
Disconnect one of the power connections and reconnect
to the EXATIG
Let the product cool down
Use a generator with an output voltage between 10V
and 114V
Clean the workpiece
Make sure the earth has a good contact with the
workpiece
Replace the torch
Turn on EXAGON
Connect the interconnect cable
Replace the interconnect cable
Disconnect EXATIG from EXAGON.
A
C
G
F
E
J
K
Connector
Connection terminal
Pink
Grey
EN
K
J
H
G
F
E
D
C
B
A