Genius SPRINT 03 Manual Del Usuario página 18

Ocultar thumbs Ver también para SPRINT 03:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 39
5.1.3. A
ccessories
"+24V – -24V" terminals. The accessories power cables should be connected to these terminals.
The maximum load of the accessories must not exceed 500 mA.
The output of these terminals is DC - observe the power supply polarity of the accessories.
5.1.4. e
Arth
"
" Terminal. The control unit earthing line should be connected to this terminal.
This connection is absolutely necessary to ensure a correctly operating control unit.
5.2. TERMINAL BOARD CN2
5.2.1. g
eArmotor
"APM1 – CHM1" terminals. Connect the motor power cables
to these terminals. The maximum load applied to these
terminals must not exceed 70W
5.2.2. F
/ c
lAshing lAmp
"LAMP – LAMP" terminals. Both a flashing lamp and a courtesy
light can be connected to these terminals, both powered
on 24 Vdc and a maximum of 15W. To make this output
operational, select parameter "G", see paragraph 9.
Flashing lamp operation:
During normal operation, the flashing lamp operates only
when the leaves are moving. When the leaves are idle, both
during opening and closing, the flashing lamp stays off.
We advise you to connect the flashing lamp before
programming the control unit, because it indicates
its phases.
Use a steady light flashing lamp; flashing is controlled
by the control unit.
Courtesy light operation:
The courtesy light stays on for the entire cycle time. At the end of the cycle, the light stays on for another 2 minutes.
The activation time of the courtesy light cannot be changed. Use a lamp powered at a maximum of 24 V 15W.
5.3. TERMINAL BOARD CN3
5.3.1. c
losure trAVel limit deVice
"COMF – FCC" terminals. Normally closed contact. It
intervenes on the gate's closing motion, defining the start of
the slowed down section. The status of this input is signalled
by LED FCC.
5.3.2. o
pening trAVel limit deVice
"COMF – FCA" terminals. Normally closed contact. It
intervenes on the gate's opening motion, defining the
start of the slowed down section. The status of this input is
signalled by LED FCA.
• The travel limit devices cannot be used to stop
gate motion immediately
5.3.3. e
ncoder
"SIG. - -ENC - +ENC" terminals. Use the encoder supplied with
the control unit. Connect the return signal from terminal "S"
of the encoder to terminal "SIG"; to terminal "-ENC" connect
terminal "V-" of the encoder and to terminal "+ENC" connect
terminal "V+" of the encoder.
Use of the encoder is absolutely necessary for correct operation of the control unit.
To ensure correct operation of the encoder, respect the connection described above.
ourtesy light
6

Capítulos

Tabla de contenido
loading

Este manual también es adecuado para:

Sprint 04

Tabla de contenido