Wilo Drain TP 80 Serie Instrucciones De Instalación Y Funcionamiento página 17

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

ENGLISH
Cause:
The pump runs against the insulating air cushion.
remedy:
Stationary wet-well installation:
Ventilate backflow preventer via adjusting screw.
Tighten adjusting screw again after ventilation.
If it is very difficult for the customer to access the
backflow preventer, raise the pump on the chain
approx. 3 cm and wait until no more air bubbles
appear. Lower pump again.
Stationary, horizontal dry installation:
Ventilate flange pipe (fig. 2c, pos. 19) by opening
stop valve (pos. 20). Close stop valve again after
ventilation.
12
remedy:
Stationary, vertical dry installation:
Ventilate backflow preventer via adjusting screw, or
on pipe bend (fig. 2d pos. 4B) by opening
valve, (pos. 20). Tighten adjusting screw/stop valve
again after ventilation.
If no solution can be found, please contact your plumbing
and heating specialist or your nearest WILO customer
services or representative.
1
/
"
2
1
Subject to technical alterations!
/
" stop
2
Tabla de contenido
loading

Este manual también es adecuado para:

Drain tp 100 serieDrain tp 150 serie

Tabla de contenido