Display
Parameter
Value
Service request: This function is used to activate a maintenance request after a selected number of cycles. When the set
number of cycles has been reached, the flashing lamp or the luminous strips on the upright sides flash rapidly
for about five seconds and the value "AS" is shown on the control unit display. To reset the number of cycles
operate as shown in paragraph 9.1
0
Service request disabled
1
Service request after 20,000 cycles
2
Service request after 40,000 cycles
3
Service request after 60,000 cycles
4
Service request after 80,000 cycles
U
5
Service request after 100,000 cycles
6
Service request after 120,000 cycles
7
Service request after 140,000 cycles
8
Service request after 160,000 cycles
9
Service request after 180,000 cycles
Cycle counter: The number of cycles, in thousands, performed by the automated system is displayed. For example, if value "01"
is shown on display, this means that the automated system has performed 10,000 cycles, if value "12" is shown,
the automated system has performed 120,000 cycles
00
Shows the number of cycles performed
a The immediate closure function can be activated only if the automatic re-closure of the automated system has been
selected and with photocells active only at closing, parameter "y 0".
b The immediate closure/Timer function can be activated only if the automatic re-closure of the automated system has
been selected.
c For the operation of the fototest function, connect the negative pole of the power supply of the photocell transmitters
to terminal "23".
d When the set number of cycles has been reached, normal operation of the automated system is not inhibited.
e The counter can count up to 180,000 cycles max.; value "18" is displayed. Afterwards, the count stops.
The conditions shown on the table refer to default values of the control unit. We recommend you to make a note of the
modifications carried out in order to restore them if the control unit is replaced.
You can access and modify the operating parameters only when the automated system is closed and at rest. The display
must indicate value "--".
Every time you modify the operating parameters, it is advisable to perform a new programming operation of the control
unit.
9.1. Resetting the cycle number for service request
When the set number of cycles has been reached, you need to reset the counter manually, performing the following
procedure:
1.
Access the adjustment phase of the operating parameters, see paragraph 9.
2.
Scroll all the parameters until the number of cycles is displayed.
3.
Press and hold down push-buttons P1 and P2 for about 10 seconds.
4.
When value "00" appears on the display, this means that the deletion has been performed.
5.
Press again push-button P1 or wait 60 seconds to return to normal operation of the automated system.
Description
.
d
.
e
LYNX 07 24V
Page 2
Guide for the installer