Display
Parameter
Value
Motor power / encoder sensitivity: This function controls the encoder sensitivity when detecting an obstacle. The encoder
1
High encoder sensitivity, minimum motor power
2
Medium-high encoder sensitivity, medium-low motor power
b
3
Medium-low encoder sensitivity, medium-high motor power
4
Low encoder sensitivity, high motor power
Automatic re-closure: This parameter is used to enable or disable the automatic re-closure of the barrier and to select the
relevant pause time.
0
Automatic re-closure disabled
1
Automatic closure enabled with a 5-second pause
2
Automatic closure enabled with a 10-second pause
3
Automatic closure enabled with a 20-second pause
c
4
Automatic closure enabled with a 40-second pause
5
Automatic closure enabled with a 60-second pause
6
Automatic closure enabled with a 120-second pause
7
Automatic closure enabled with a 240-second pause
Function of the OPEN/CLOSE command: This function determines the behaviour of the OPEN/CLOSE command.
0
Opens/Closes/Opens/.....
d
1
Opens/Stop/Closes/Stop/Opens/.....
Condo function:
This parameter activates the condo function. If this function is activated, during the opening phase, the
0
Condo function disabled
E
1
Condo function activated
Rod light:
This parameter is used to select the operating type of the luminous strip on the rod, if any.
0
Rod light ON with open or closed rod, it flashes when the rod is moving.
G
1
Rod light OFF with open or closed rod, it flashes when the rod is moving
Slow-down percentage:
1
Short slow-down
2
Medium-short slow-down
H
3
Medium-long slow-down
4
Long slow-down
Slow motion speeds: With this parameter you can select the speed of the bar during the downturn.
O
Low Speed
I
1
High Speed
sensitivity is inversely proportional to motor power.
control unit ignores any OPEN or OPEN/CLOSE commands. .
This parameter is used to select the length of the decelerated section before the travel limit
Description
operates, on four pre-set levels.