EN
DE ES IT FR PT NL RU FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET
CHARGING PROCEDURE
NOTE: The battery is not shipped fully
charged. It is recommended to fully charge
before use to ensure that maximum run time
can be achieved. This lithium-ion battery will
not develop a memory and may be charged
at any time.
2900313
1. Plug the charger into an AC power outlet.
2. Insert the battery pack (1) into the charger
(2).
1
2904813
1. Charge one battery:
–Plug the charger (1) into an AC power
outlet.
–Insert the battery pack (2) into the
charger (1).
2. Charger two batteries:
–Plug the charger (1) into an AC power
outlet.
–Insert two battery packs (2) into the
charger (1).
Note: When charging two battery packs, the
two batteries are charged separately. The
charger will charge one battery first. After one
battery is fully charged, it will charge the other
battery.
English (Original Instructions)
3
2
2
This is a diagnostic charger. The Charger
LED Light (3) will illuminate in specific order
to communicate the current battery status.
They are as follows:
LED STATUS
Blinking Green
Solid Green
Solid Red
Blinking Red
False Defect Note:
When the battery is inserted into the charger,
and the status LED flashes, remove the
battery from the charger for 1 minute, then
reinsert. If the status LED indicates normal
than the battery pack is good. If the status
LED is still blinking, remove the battery pack
and unplug the charger. Wait 1 minute and
plug the charger back in and reinsert the
battery pack. If the status LED indicates
normal than the battery pack is good. If the
status LED is still blinking then the battery
pack is defective and needs to be replaced.
NOTE: When the red indictor flickers, pull out
the battery from the charger and insert again
within 2 hours. If the indictor shows charging,
that means the battery is good. After 2 hours,
please pull out the battery and also pull
out the AC power plug of the charger for 1
miniute, and then insert the AC power plug
and the battery again. If the indictor shows
5
3
1
DESCRIPTION
Charging
Fully Charged
Over Temperature
Charging Fault