PLEASE READ CAREFULLY THROUGH THIS MANUAL BEFORE USING THE PRODUCT,
OBSERVING ALL SAFETY INFORMATION, WARNINGS.
1. WARNING
This product is intended for installation by a
qualified service person.
•
Disconnect power at the service breaker
before installing or servicing.
•
Failure to properly ground unit could
result in severe electrical shock.
•
All units must be supplied with a 3-wire
connection. The ground wire must be
connected to the dryer's backplate.
3. SPECIFICATION
Voltage:
220V-240V 50/60Hz, 8A, 1800W(Hot) / 2.4A, 550W(Cold)
110V-120V, 60Hz, 16A, 1800W(Hot) / 4.8A, 550W(Cold)
Air Temperature: 45°C (D=10CM,Room Temp.=25°C)
Air Velocity:
Air Flow:
Drying Time:
Sensor Range:
Protection Level: IPX1
Electric Isolation: CLASS 1
Brush Motor:
Noise(at 1M):
Cabinet Material: Stainless Steel 304
4. INSTALLATION
1.
Installation must be carried out in
accordance with the current edition
of the local wiring regulations code
having jurisdiction. Installation should
be performed only by a qualified
electrician.
2.
Place template against wall at
desired height (see mounting height
recommendations) and mark locations
of 4 mounting holes Dia. 8mm (5/16").
3.
Remove and retain 2 side security hex
cover screws and cover. Then mount
the hand dryer base on the wall.
4.
Before replacing the cover, there is
an option to run the dryer heater on
5. OPERATION
•
No-touch operation.
•
There is a blue LED light to guide user
to the air flow.
•
Shake excess water from hands.
2
60M/S
140M3/H
8-10S
5-15CM
25000R/M
74dB
Terminal
Block
Brown
Motor
2. NOTE
Do not install dryer over washbasin.
If the power supply cord is damaged, it
must be replaced by the manufacturer or its
service agent or a similar qualified person
in order to avoid a hazard. Means for
disconnection must be incorporated in the
fixed wiring in accordance with the current
wiring regulations.
(1800 Watts) or heater off (550 Watts).
L
220 - 230V 50/60Hz
N
OR 110 - 120V 60Hz
The switch is clearly marked.
E
5.
Earthing
Heat Element
Replace cover. Do not over-tighten
screws.
HOT/COLD Switch
6.
Connect the hand dryer plug to the
Yellow
power supply.
Blue
a. Connect the live wire (coloured
Heating
Brown or Red) to the terminal block
Motor
marked "L".
Power
Blue
b. Connect the neutral wire (coloured
Brown
Black or Blue) to the terminal block
marked "N".
c. Connect the ground wire (coloured
Green or Yellow) to the terminal block
Power
marked "E".
•
Place hands under the outlet to start
operation.
•
Rub hands lightly and rapidly.
•
Stops automatically after hands are
removed.
170MM
Sensor Board
Turn clockwise to
increase sensor range
Blue LED Light
Program Board
Transformer
Relay
Hand Dryer Main Circuit Board