Models : Max Gas 40 P- 70 P- 105 P - 120 P
Max. gas pressure*
Min. gas pressure*
Fuel L.C.V.
Model : Max Gas 40 P
Gas flow rate
Model : Max Gas 70 P
Gas flow rate
Model : Max Gas 105 P
Gas flow rate
Model : Max Gas 120 P
Gas flow rate
* : Minimum/maximum gas inlet pressures depend by the gas train matched to the burner. The values are written on the gas trains manual.
Termal power max.
Termal power max.
Gas family :
mbar
4
3,5
3
2,5
2
1,5
1
0,5
0
10
10
Max Gas 40 P
OPERATING FEATURES
mbar
mbar
kcal/Nm
3
max.
min.
max.
min.
max.
min.
max.
min.
TECHNICAL DATA
Max Gas 40 P
kW
48
kcal/h
41.380
kW
17
kcal/h
14.650
AT
I
I
BE
2H,
3B/P
ES
I
I
FI
2H,
3P
GR
I
I
IE
2H,
3B/P
SE
I
I
NL
2H,
3B/P
WORKING FIELDS
MAX GAS 70 P
MAX GAS 40 P
20
30
40
20
30
40
50
OVERALL DIMENSIONS
A
B
C
420010385903 Max Gas 40 P - 70 P - 105 P - 120 P
420010385902 Max Gas 40 P - 70 P - 105 P - 120 P
Gas family
G20
G25
360
360
12
12
8.570
7.370
4,83 Nm
/h
5,61 Nm
/h
3
3
1,71 Nm
/h
1,99 Nm
/h
3
3
7,04 Nm
/h
8,19 Nm
/h
3
3
3,42 Nm
/h
3,98 Nm
/h
3
3
11,21 Nm
/h
13,04 Nm
/h
3
3
4,93 Nm
/h
5,73 Nm
/h
3
3
12,07 Nm
/h
14,04 Nm
/h
3
3
4,93 Nm
3
/h
5,73 Nm
3
/h
Max Gas 70 P
Max Gas 105 P Max Gas 120 P
70
60.340
96.100
34
29.310
42.240
I
I
DE
I
I
2E(R)B,
3P
2E,
3B/P
I
I
FR
I
I
2H,
3B/P
2Er,
3B/P
I
I
IT
I
I
2H,
3B/P
2H,
3B/P
I
I
2L,
3B/P
MAX GAS 105 P
50
60
70
80
60
70
80
90
Output
D-D1
E
N
7
G31
G30
360
360
30
30
22.260
29.320
1,86 Nm
/h
1,41 Nm
/h
3
3
0,66 Nm
/h
0,50 Nm
/h
3
3
2,71 Nm
/h
2,06 Nm
/h
3
3
1,32 Nm
/h
0,99 Nm
/h
3
3
4,32 Nm
/h
3,28 Nm
/h
3
3
1,90 Nm
/h
1,44 Nm
/h
3
3
4,65 Nm
/h
3,53 Nm
/h
3
3
1,90 Nm
3
/h
1,44 Nm
3
/h
108
120
103.450
49
49
42.240
DK
I
I
2H,
3B/P
GB
I
I
2H,
3B/P
PT
I
I
2H,
3B/P
MAX GAS 120 P
kcal/h
90
100
x 1000
kW
100
110
120
125
I
M
EN