Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 10
GB
Fold out pages:
Application
Prod. No. 36 093:
Single-hole mixer suitable for:
• Direct connection to cold water supply
• Connection to outlet of upstream mixed water supply
Prod. No. 36 092 and 36 094:
Can be used in conjunction with:
• Pressurised storage heaters
• Thermally-controlled instantaneous heaters
• Hydraulically-controlled instantaneous heaters
Operation with unpressurised storage heaters (displacement
water heaters) is not possible.
Safety notes
• Installation is only possible in frost-free rooms.
• Use only genuine replacement parts and accessories.
The use of other parts will result in voiding of the warranty
and the CE identification.

Technical data

• Flow pressure:
min. 0.5 bar - recommended 1-5 bar
• Operating pressure:
• Test pressure:
If static pressure exceeds 5 bar, a pressure-reducing valve
must be fitted.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 3 bar flow pressure:
• Hot water supply temperature:
Recommended (energy economy):
• Voltage supply:
6 V lithium battery (type CR-P2)
• Automatic safety shut-off
(factory setting):
• Run-on time (factory setting):
• Reception range with Kodak Gray Card,
grey side, 8 x 10", landscape, 5cm below the spout
(factory setting):
• Type of protection:
• Battery check:
• Water connection:
The test for electromagnetic compatibility (interference
emission test) was performed at the rated voltage and rated
current.
Special accessories
Infrarot-Fernbedienung (Best.-Nr.: 36 206) zur Änderung
der Werkseinstellungen und Wahl von Sonderfunktionen.
Approval and conformity
This product conforms to the requirements of the
relevant EU guidelines.
The conformity declarations can be obtained from the following
address:
GROHE Deutschland Vertriebs GmbH
Zur Porta 9
D-32457 Porta Westfalica
3
Installation
Flush pipes thoroughly before and after installation
(observe EN 806).
Fitting
Refer to the dimensional drawings on fold-out page I.
Lift rod (A) must be inserted into the mixer body during
installation, see fold-out page II, Fig. [1].
Fasten fitting to wash basin, see Figs. [1] to [3].
Connection
The cold water supply must be connected on the right, hot
water supply on the left.
In order to ensure permanent, trouble-free operation, fitting
of the enclosed adapter is mandatory.
Insert filter (B) and screw adapter (C) together with seal (C1)
onto the service valve, see Fig. [4].
Open hot and cold water supply and check connections
for watertightness.
Setting temperature limiter
Prod. No. 36 092 and 36 094:
1. Remove screw (D), see Fig. [5].
2. Turn mixer lever (E) clockwise until the desired maximum
max. 10 bar
temperature is reached.
16 bar
3. Detach mixer lever (E), see Fig. [6].
4. Detach stop ring (F) and reattach with notch (F1) pointing
vertically upwards.
5. Turn mixer spindle (G) anti-clockwise to the stop.
6. Attach mixer lever (E) in horizontal position and fasten
approx. 6 l/min
with screw (D).
max. 70 °C
60 °C
Operation
The infrared electronics emit invisible, pulsed light. The
60 s
infrared-electronics are adjusted so that water flow is initiated
1 s
when the hands approach the vicinity of the spout.
When the hands are withdrawn from the vicinity of the spout,
water flow is stopped after 1 s (factory setting).
approx. 15cm
The range of the sensor system is dependent upon the
IP 59 K
reflective properties of the detected object.
Flashing signal
Automatic safety shut-off
cold - right
hot - left
After 60 s (factory setting) of continuous detection of an object,
the infrared electronics automatically stop the water flow.
Automatic flushing (factory setting: not activated)
Automatic flushing serves to ensure water hygiene in the event
of long-term non-utilisation of the fitting. and activates water
flow for 1-10 minutes, 1 or 3 days after the last use.
Safety notes:
- Ensure free draining in the case of activated automatic
flushing.
- For automatic flushing of the hot and cold water lines,
the fitting must be in the mixed water setting.
Cleaning
For cleaning purposes, the fitting can be switched off by
attaching the enclosed cleaning clip (K), see Fig. [7].
Tabla de contenido
loading

Este manual también es adecuado para:

36 09336 094Essence e 36 092Essence e 36 093Essence e 36 094

Tabla de contenido