DuraHeat DFA-45T Manual Del Usuario página 12

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
9. MAINTENANCE
WARNING!! : NEVER SERVICE HEATER WHILE IT IS PLUGGED IN OR
WHILE HOT!
USE ORIGINAL EQUIPMENT REPLACEMENT PARTS. Use of third party or
other alternate components will void warranty and may cause unsafe operating
conditions.
A.) FUEL TANK
FLUSH EVERY 200 HOURS OF OPERATION
OR AS NEEDED (SEE STORAGE, PAGE 10)
B.) AIR INTAKE FILTER
WASH AND DRY WITH SOAP AND WATER
EVERY 500 HOURS OF OPERATION OR AS
NEEDED.
- Remove screws along each side of heater using
medium phillips screwdriver.
- Lift upper shell off.
- Remove fan guard.
- Wash or replace air intake filter.
- Reinstall fan guard and upper shell.
C.) AIR OUTPUT FILTER, LINT FILTER
REPLACE EVERY 500 HOURS OF
OPERATION OR ONCE A YEAR.
- Remove upper shell and fan guard (See Air Intake
Filter).
- Remove end filter cover screws using medium
phillips screwdriver.
- Remove end filter cover.
- Replace air output and lint filter.
- Reinstall end filter cover.
- Reinstall fan guard and upper shell.
D.) FAN BLADES
CLEAN EVERY SEASON OR AS NEEDED.
- Remove upper shell (See Air Intake Filter).
- Use M6 allen wrench to loosen set screw
which holds fan blade to motor shaft.
- Slip fan blade off motor shaft.
- Clean fan blade using a soft cloth moistened with
kerosene or solvent.
- Dry fan blade thoroughly.
- Reinstall fan blade on motor shaft. Place fan
blade hub flush with end of motor shaft.
- Place set screw on flat of shaft. Tighten set screw
firmly (40-50 inch-pounds/4.5-5.6 N-m).
- Reinstall upper shell.
Lint Filter
Motor Shaft
11
Upper Shell
Air Intake Filter
Fan Guard
Figure 12
Air Output Filter
Intake Filter
End filter cover
Figure 13
Set screw
Motor Shaft
Fan Blade
Figure 14
Flush
Tabla de contenido