EN
Change charging cable
4
Take the charging cable out of the box.
Check that the rubber sealing ring on the charging plug is in
place and not twisted. This is to ensure that the proper IP code
(protection class) is met.
Place the charging station on its side and then plug the
charging cable into the station.
5
Turn the station around and place the front face of the station
on a soft and stable surface.
Insert the bolt and tighten it firmly with the supplied Torx T30
bit.
6
Reconfirm that the cable bolt is tightened properly.
Check again that the charging cable is connected firmly to the
station.
Warning: double check that the charging cable plug is properly
secured into the station with the bolt.
7
Align the station to the wall dock and the connectors and press until you hear a clicking
sound. Keep a straight line while mounting the station. To ensure that the connection is fully
secured, press firmly on all four corners and check that there is no air gap between the wall
dock and the station.
CLICK
8
When upgrading your charging cable to a version that is suitable for higher power
application, make sure that the applied RCD and MCB in the service panel are in line with
local regulations, and are also adequate for the type of charging cable installed and the
amount of power Elvi can supply (3.7, 7.4, 11 or 22 kW).
Check with your installer whether the selected output power from your Elvi can be supported
by your local electrical installation. The setting of your maximum available amperage in the
mobile app and/or web platform for station management may need to be adjusted to the
new situation.
11