No.
Parameter
A085 [Start Boost]
Only active when A084 [Boost Select] and A125 [Torque Perf Mode] are set to "0".
A086 [Break Voltage]
Only active when A084 [Boost Select] and A125 [Torque Perf Mode] are set to "0".
A087 [Break Frequency]
Only active when A084 [Boost Select] and A125 [Torque Perf Mode] are set to "0".
A088 [Maximum Voltage]
A089 [Current Limit 1]
A090 [Motor OL Select]
A091 [PWM Frequency]
A092 [Auto Rstrt Tries]
A093 [Auto Rstrt Delay]
A094 [Start At PowerUp]
A095 [Reverse Disable]
A096 [Flying Start En]
A097 [Compensation]
A098 [SW Current Trip]
A099 [Process Factor]
A100 [Fault Clear]
A101 [Program Lock]
A102 [Testpoint Sel]
A103 [Comm Data Rate]
Power to drive must be cycled before any
changes will affect drive operation.
A104 [Comm Node Addr]
Power to drive must be cycled before any
changes will affect drive operation.
A105 [Comm Loss Action] 0/3
A106 [Comm Loss Time]
A107 [Comm Format]
Power to drive must be cycled before any
changes will affect drive operation.
A108 [Language]
A109 [Anlg Out Setpt]
A110 [Anlg In 0-10V Lo]
A111 [Anlg In 0-10V Hi]
A112 [Anlg In4-20mA Lo]
A113 [Anlg In4-20mA Hi]
A114 [Slip Hertz @ FLA]
A115 [Process Time Lo]
A116 [Process Time Hi]
A117 [Bus Reg Mode]
A118 [Current Limit 2]
A119 [Skip Frequency]
A120 [Skip Freq Band]
See the PowerFlex 40 User Manual on CD for more information on parameters.
Min/Max
Display/Options
0.1%
0.0/25.0%
0.1%
0.0/100.0%
0.1 Hz
0.0/400.0 Hz
20/Rated Volts
1 VAC
0.1/(Drive Amps × 1.8) 0.1 Amps
0/2
0 = "No Derate"
2.0/16.0 kHz
0.1 kHz
0/9
1
0.0/300.0 Secs
0.1 Secs
0/1
0 = "Disabled"
0/1
0 = "Rev Enabled"
0/1
0 = "Disabled"
0/3
0 = "Disabled"
1 = "Electrical"
0.0/(Drive Amps × 2)
0.1 Amps
0.1/999.9
0.1
0/2
0 = "Ready/Idle"
0/9999
0 = "Unlocked"
400/FFFF
1 Hex
0/5
0 = "1200"
1 = "2400"
2 = "4800"
1/247
1
0 = "Fault"
1 = "Coast Stop"
0.1/60.0 Secs
0.1 Secs
0/5
0 = "RTU 8-N-1"
1 = "RTU 8-E-1"
2 = "RTU 8-O-1"
1/10
1 = "English"
2 = "Français"
3 = "Español"
4 = "Italiano"
5 = "Deutsch"
0.0/100.0%
0.1%
0.0/100.0%
0.1%
0.0/100.0%
0.1%
0.0/100.0%
0.1%
0.0/100.0%
0.1%
0.0/10.0 Hz
0.1 Hz
0.00/99.99
0.01
0.00/99.99
0.01
0/1
0 = "Disabled"
0.1/(Drive Amps × 1.8) 0.1 Amps
0/400 Hz
1 Hz
0.0/30.0 Hz
0.1 Hz
Default
2.5%
25.0%
15.0 Hz
Rated Volts
Amps × 1.5
1 = "Min Derate"
0
2 = "Max Derate"
4.0 kHz
0
1.0 Secs
1 = "Enabled"
0
1 = "Rev Disabled"
0
1 = "Enabled"
0
2 = "Mechanical"
1
3 = "Both"
0.0 (Disabled)
30.0
1 = "Reset Fault"
0
2 = "Clear Buffer"
1 = "Locked"
0
400
3 = "9600"
3
4 = "19.2K"
5 = "38.4K"
100
2 = "Stop"
0
3 = "Continu Last"
5.0 Secs
3 = "RTU 8-N-2"
0
4 = "RTU 8-E-2"
5 = "RTU 8-O-2"
6 = "Reserved"
1
7 = "Português"
8 = "Reserved"
9 = "Reserved"
10 = "Nederlands"
0.0%
0.0%
100.0%
0.0%
100.0%
2.0 Hz
0.00
0.00
1 = "Enabled"
1
Amps × 1.5
0 Hz
0.0 Hz
Tabla de contenido
loading

Tabla de contenido