Heath Zenith SL-4300 Manual De Instrucciones página 5

Ocultar thumbs Ver también para SL-4300:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

The sensor is less sensitive to motion directly
towards it and more sensitive to motion across
coverage area.
Motion
Sensor
Least Sensitive
aDJustment OF cOverage
area
The sensor on this light fixture detects "motion"
by the movement of heat (body heat) across the
coverage area. However, following are examples
of objects that also produce heat and can cause
the sensor to false trigger:
• Pools of Water
• Air Conditioners
• Dryer Vents
• Fenced-In Animals
• Heating Vents
• Automobile Traffic
If you suspect that a heat source of this type is falsely
triggering the sensor and reducing the sensitivity
does not solve the problem, then a lens shield
(included) can be installed. The plastic lens shield
is divided into 6 sections. Each section will reduce the
coverage angle by 30 degrees. Also, the tip of each
section may be removed to change the effective
range of the sensor.
Lens
Shield
Effective
Coverage Area
(Top View)
Lens
Shield
Portion
Removed
598-1183-03
Motion
Most Sensitive
Area
Blocked
Area
Blocked
1. Break off the
amount of lens
shield needed
to block the de-
sired area of
coverage.
2. C u t d e s i r e d
amount of foam
tape needed to
adhere the lens
shield to the sensor lens.
3. Remove paper backing from one side of cut
foam tape and adhere foam tape to inside of
lens shield.
4. Remove paper backing from other side of cut foam
tape and adhere lens shield to sensor lens.
5. Retest to confirm that the sensor is no longer
false triggering.
Note: To help determine amount of lens shield
required, apply small sections one at a time. Ad-
ditional sections can be applied if necessary.
sPeciFicatiOns
Range ........................... Up to 30 ft. (9.1 m)
Sensing Angle .............. 360°
Electrical Load . ............. Up to 100 Watt
Bulb Type ...................... Candelabra Base, Type
Sensor Capacity ........... Up to 200 Watt (1.7 A.)
Power Requirements .... 120 VAC, 60 Hz
Operating Modes .......... TEST, AUTO/ACCENT,
ON-Timer . ..................... 1, 5, 10 minutes
D
B
Timer .......... Off, 3, 6 Hrs, Dusk-to-
®
ual
rite
HeathCo LLC reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.
5
Lens Shield
®
IT E
B R
A L
D U
S K
W N
D U
D A
T O
6
3
F
O F
M IN
1 0
5
E
1
- T IM
S T
T E
O N
Sensor Lens
[varies with surrounding
temperature].
Maximum Tungsten
Incandescent (Up to 25
Watt Maximum each
lampholder).
"B", 25 Watt Maximum
Maximum Tungsten
Incandescent
and MANUAL MODE
Dawn
Tabla de contenido
loading

Tabla de contenido