MAINTENANCE BY
THE SERVICE
To ensure the perfect operation of the pumps dosing the chemical products, it is
recommended to have them maintained every three months.
Every 12 months
Request a general maintenance that will include among other things:
-
Cleaning and if necessary replacement of the internal filters;
-
Cleaning and if necessary replacement of the electromagnetic valve's membranes;
-
Cleaning of the pump to ensure its perfect rotation;
-
Control and if necessary cleaning of the thermostat's probes;
-
Replacement of the dosage pump's membrane.
T
HIS GENERAL MAINTENANCE IS NECESSARY ALSO FOR INSTALLATION USING SOFT
; T
WATERS
HE HIGH WATER TEMPERATURE INSIDE THE MACHINE FACILITATES THE
DEPOSIT OF SCALE ON THE HEATING RESISTORS AND THE OBSTRUCTION OF THE
NOZZLES SO AFFECTING THE WASHING AND THE ACHIEVEMENT OF THE DISINFECTION
TEMPERATURE IN THE TANK
NOTE
.
21