Pool Pump Suction Entrapment Prevention Guidelines - Polaris PB Serie Manual De Instalación Y Funcionamiento

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

ENGLISH
Page 6
1.2

Pool Pump Suction Entrapment Prevention Guidelines

Pump suction is hazardous and can trap and drown or disembowel bathers. Do not use or operate
swimming pools, spa, or hot tubs if a suction outlet cover is missing, broken, or loose. The following
guidelines provide information for pump installation that minimizes the risk of injury to users of pools, spas, and hot
tubs:
Entrapment Protection - The pump suction system must provide protection against the hazards of suction
entrapment.
Suction Outlet Covers - All suction outlets must have correctly installed, screw-fastened covers in place. All
suction outlet (drain) covers must be maintained. Drain covers must be listed/certified to the latest version of
ANSI
/ASME
A112.19.8. They must be replaced if cracked, broken, or missing.
®
®
Number of Suction Outlets Per Pump - Provide at least two (2) hydraulically-balanced main drains, with covers,
as suction outlets for each circulating pump suction line. The centers of the main drains (suction outlets) on any
one (1) suction line must be at least three (3) feet apart, center to center. See Figure 1.
The system must be built to include at least two (2) suction outlets (drains) connected to the pump whenever
the pump is running. However, if two (2) main drains run into a single suction line, the single suction line may be
equipped with a valve that will shut off both main drains from the pump. The system shall be constructed such that
it shall not allow for separate or independent shutoff or isolation of each drain. See Figure 1.
More than one (1) pump can be connected to a single suction line as long as the requirements above are met.
Water Velocity - The maximum water velocity through the suction fitting or cover for any suction outlet must be
1.5 feet per second unless the outlet complies with the latest version of ANSI/ASME A112.19.8, the standard for
Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs. In any case, do not exceed the
suction fitting's maximum designed flow rate.
If 100% of the pump's flow comes from the main drain system, the maximum water velocity in the pump suction
hydraulic system must be six (6) feet per second or less, even if one (1) main drain (suction outlet) is completely
blocked. The flow through the remaining main drain(s) must comply with the latest version of ANSI/ASME
A112.19.8, the standard for Suction Fittings For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.
Testing and Certification - Suction outlet covers must have been tested by a nationally recognized testing
laboratory and found to comply with the latest version of ANSI/ASME A112.19.8, the standard for Suction Fittings
For Use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.
Fittings - Fittings restrict flow; for best efficiency use fewest possible fittings (but at least two (2) suction outlets).
Avoid fittings which could cause an air trap.
Pool cleaner suction fittings must conform to applicable International Association of Plumbing and Mechanical
Officials (IAPMO
) standards.
®
Listed/certified to latest
Cover/Grate or Suction
Fitting, screw-fastened
Suction Outlet
(Main Drain)
Figure 1.
Number of Suction Outlets Per Pump
Polaris® PB4-60 Booster Pump | Installation and Operation Manual
published version of
ANSI/ASME
A112.19.8 - 2007
Anti-entrapment
to Main Drain Sump
Valves OK between
pump and Tee
WARNING
At least
three (3) feet
No valves between
Tee and Main Drains
Listed/certified to latest
published version of
ANSI/ASME
A112.19.8 - 2007
Anti-entrapment
Cover/Grate or Suction
Fitting, screw-fastened
to Main Drain Sump
Suction Outlet
(Main Drain)
Pump
Tabla de contenido
loading

Este manual también es adecuado para:

Pb4-60

Tabla de contenido