Kohler K-13460 Manual De Instrucciones página 13

Ocultar thumbs Ver también para K-13460:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting (cont.)
Symptoms
Probable
Causes
K. Solenoid is
not working.
2.
Low flow.
A. Filter is
plugged.
B. Supply
pressure is
low.
C. Aerator is
plugged.
3.
Constant
A. Filter is
water flow.
plugged.
B. Diaphragm
seal is
damaged or
dirty.
C. Solenoid is
not working.
4.
Sporadic
A. The faucet
water flow.
is angled
incorrectly to
deck or
misaligned
with user area.
B. The wires
are pinched or
damaged.
5.
Sensor
A. The battery
flashes once
power is low.
approximately
every 2
seconds. The
product
continues to
operate.
Kohler Co.
Recommended Action
K. Order a new solenoid service
kit.
A. Clean or replace the filter.
B. Check incoming water pressure.
Pressure should be at least 20 psi
(137 kPa).
C. Remove the aerator and clean it.
For calcium/mineral deposits, soak
the aerator plastic insert in a 50:50
mixture of vinegar and water. Soak
only the insert and no other
components.
A. Clean or replace the filter.
B. If the diaphragm is cut or torn,
order a new diaphragm assembly.
Clean or replace the diaphragm.
C. Order and install a new solenoid
assembly.
A. Verify that the faucet is mounted
according to the installation
directions. Ensure that the faucet is
installed in a position that is above
the rim of the sink.
B. Remove the spout and verify
that the wires are tucked inside the
spout before reassembling.
A. Remove faucet from body and
replace batteries. Use two standard
AAA batteries.
13
1102759-5-D
Tabla de contenido
loading

Este manual también es adecuado para:

K-13461K-13466K-13467K-13472K-13473

Tabla de contenido