Installation Guide
Wallplate installation
1. Separate wallplate from thermostat.
2. Mount wallplate as shown below.
Remove battery holder.
Pull here to remove wallplate
from new thermostat.
Drill 3/16" holes for drywall. Drill 7/32" holes for plaster.
Wall anchors
CAUTION: ELECTRICAL HAZARD
Can cause electrical shock or equipment damage. Disconnect power before
beginning installation.
MERCURY NOTICE
If this product is replacing a control that contains mercury in a sealed tube, do not
place the old control in the trash. Contact your local waste management authority for
instructions regarding recycling and proper disposal.
It's easier to grasp the wallplate
and remove it after completely
removing the battery holder.
Insert reference card after wallplate is
mounted (see instructions, below).
Wire hole
Wallplate
Mounting screws