ENGLISH
Keep children away from the
battery charger and the working
area!
Keep your battery charger out of
reach of children!
Pull out the mains plug immediately
if the battery charger starts to
smoke or flames emerge!
Do not insert objects into the
ventilation slots on the battery
charger – there is a danger of
electric shocks and short circuits!
Do not use faulty battery packs.
5. Overview
See page 2.
1 Battery pack (not in scope of delivery)
2 Sliding seat
3 Operation display
4 Warning display
6. Commissioning
Before plugging in, check to see that the
rated mains voltage and mains frequency, as
specified on the rating label, match your
power supply.
Devices such as this one, which generate direct
current, may have an effect on basic residual-
current circuit breakers. Use type F or better, with a
release current of max. 30 mA.
Before commissioning the charger, ensure that
the air slots are free. Minimum distance to other
objects is 5 cm.
6.1
Self-test
Insert mains supply plug.
The warning display (4) and the operating indicator
(3) light up one after the other for approx. 1 second
and the installed fan runs for approx. 5 seconds.
7. Use
7.1

Charging battery pack

Push the battery pack completely to the stop on
the sliding seat (2).
The operating indicator (3) flashes.
Note: To have the charge level displayed on Li-ion
battery packs (with 14.4 V, 18 V and 36 V), first take
the battery pack out of the charger and then press
the button on the battery pack.
8
7.2

Conservation charge

Once the charging process has finished, the battery
charger automatically switches to conservation
mode.
The battery pack can remain in the battery charger
and is therefore always ready for use.
The operating display (3) lights up continuously.
8. Fault
8.1
Warning display (4) lights up
continuously
Battery pack is not charged. Temperature too high/
too low. When the temperature of the battery pack
is between 0 °C and 50 °C, the charging process
begins automatically.
8.2
Warning display (4) flashes
• Battery pack is defective. Remove the battery
pack immediately from the charger.
• The battery pack was not pushed correctly onto
the sliding seat (2). See section 7.1.
9. Repairs
Repairs to the charger must only be carried out by
qualified electricians.
If the mains connection cable of this tool is
damaged, in order to prevent endangering
personnel and property it must be replaced by the
manufacturer, or the Customer Service of the
manufacturer, or a similarly qualified person.
Contact your local Metabo representative if you
have Metabo chargers requiring repairs. For
addresses see www.metabo.com.

10. Environmental Protection

Observe national regulations on environmentally
compatible disposal and on the recycling of disused
machines, packaging and accessories.
Only for EU countries: Never dispose of
power tools in your household waste! In
accordance with European Guideline 2002/
96/EC on used electronic and electric equipment
and its implementation in national legal systems,
used power tools must be collected separately and
handed in for environmentally compatible recycling.