Erreka RINO-I Guía Rápida De Instalación Y Programación página 14

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 1
D1
D2
Parameter
C
1
Motor turning direction
3
Type of gate
4
Opening safety device (photocell or
strip)
5
Closing safety device (photocell or
strip)
Closing photocell with C520 or C521,
also prevents the start of gate opening
7
Encoder and limit switches
(when using external limit switches,
connect them to the corresponding
terminals of the control board)
8
Radio receiver
9
Safety strip type
A
Slowdown
P
1
T o t a l
programming
2
P e d e s t r i a n o p e n i n g r a d i o c o d e
programming
3
Gate travel programming
F
1
Key command using ST1 and ST2
pushbuttons
2
Operation mode (semi-automatic or
automatic) and stand-by time (in
seconds) in automatic mode
3
Pedestrian opening
4
Pedestrian closing operation mode
(semi-automatic or automatic) and
stand-by time (in seconds) in automatic
mode
14
Complete programming chart
o p e n i n g
r a d i o
c o d e
D3
D4
Pre-set option Options or values
0
1
x
0
2
0
2
x
0
3
0
0
x
1
0
1
1
0
0
x
1
0
1
1
2
0
2
1
0
0
0
2
0
4
x
0
6
0
7
0
1
0
2
x
0
1
x
0
2
0
0
0
1
x
0
2
0
3
o
ç
o
ç
o
ç
0
0
0
1
x
0
2
0
3
0
4
0...5.
0...9
00
0...9
0...9
40
0...5.
0...9
00
Sliding gate
Up&over door, with shadow function
Device not installed
Device without testing
Device with testing
Device not installed
Device without testing
Device with testing
Device without testing
Device with testing
No encoder or limit switches
With internal limit switches
With encoder and internal limit switches
With external limit switches
With encoder and external limit switches
RSD card (frame, not decoder)
Twin-channel decoder card
Contact edge
Resistive edge
No slowdown
Slowdown in opening and closing
Slowdown in opening
Slowdown in closing
ST1 and ST2 without effect, key commands
are made by radio (channel 1: total
opening-closing, channel 2: pedestrian
opening-closing)
ST1 total opening-closing, ST2 pedestrian
opening-closing
ST1 total opening, ST2 total closing
Dead-man mode
Dead-man mode in closing
00: semi-automatic mode
01: automatic mode and stand-by time 1
second; ...
59: automatic mode and stand-by time 59
sec.;
1.0: 1 min. 0 secs.; ....; maximum 4 minutes
00: Pedestrian opening is not carried out
01: 1% of total opening
12: 12% of total opening
99: 99% of total opening (equivalent to
100%)
00: semi-automatic mode
01: automatic mode and stand-by time 1
second; ...
59: automatic mode and stand-by time 59
sec.;
1.0: 1 min. 0 secs.; ....; maximum 4 minutes