3
3.3.5
Cooling
When used in this mode, the air conditioner dehumidifies and cools the room.
Activate this mode by pressing button (T4) Run mode selector until the snowflake symbol (D3) is displayed.
In this run mode, the required temperature and fan speed can be set.
After having activated this run mode, the compressor will start running after 3 minutes at the most and the unit begins emitting cold
air.
The starting of the compressor is seen by the lighting up of the relative green LED B (fig. 22) on the control panel.
3.3.6
Dehumidification only
When used in this mode, the air conditioner eliminates the humidity in the room. This function can be extremely useful between
seasons, particularly on rainy days when the temperature is not uncomfortable but the excess humidity feels unpleasant.
In this mode, both room temperature and fan speed settings are ignored, which correspond to minimum.
As such, no temperature and fan speed indications are displayed.
Activate this mode by pressing button (T4) Run mode selector until the droplet symbol (D4) and automatic ventilation symbol (D1)
are displayed.
In this operating mode it is normal for the air conditioner to function intermittently.
3.3.7
Ventilation only
When used in this mode the air conditioner does not perform any action with regard to temperature and air humidity in the room.
Activate this mode by pressing button (T4) Run mode selector until the fan symbol (D1) is displayed.
At this stage you can select the fan speed (see paragraph 3.3.11).
3.3.8
Well-being function (automatic)
The machine's temperature is automatically regulated according to the room's temperature. The fan speed is also
automatically regulated according to the set temperature (except in dehumidification mode).
Activate this mode by pressing button (T4) Run mode selector until the symbol (D7) is displayed.
3.3.9
Heating (only models fitted with heating pump)
When used in this mode the air conditioner heats the room. This function is only available on models with a heating pump (HP).
Activate this mode by pressing button (T4) Run mode selector until the sun symbol (D2) is displayed.
In this run mode, the required temperature and fan speed can be set. After three minutes (maximum time) the compressor should
start and the air conditioner starts heating the room. The start of the compressor can be checked through the lighting of the relevant
green LED located on the console.
NOTE: the air conditioner has to defrost its battery periodically. during this operation the air conditioner does not
heat the room, though its internal parts remain on except for the room air fan. when the outdoor temperature is
very low, there may be a slight delay for passage from the minimum to the medium or maximum speed from when
the command is sent to the machine with the remote control.
Like delays might occur on activating the swinging function of the mobile baffle.
After having turned off the unit, the internal fan runs 60 seconds more. Then it stops and both air flaps close.
3.3.10
Checking airflow direction
The airflow may be checked vertically.
To adjust vertical airflow you can operate in two ways:
-
continuous air flow oscillation, obtainable by pressing button T9 Activation/Deactivation of the moving flaps. By so doing, the
grille fins perform a complete oscillation.
-
block the moving flaps in the preferred position by pressing button T9 again while the fins move.
By pressing button T9 again, the automatic movement of the moving flaps starts again.
IMPORTANT: Never force manually the movement of the moving flaps.
36