Palazzetti TC 120 Manual De Usuario página 58

Ocultar thumbs Ver también para TC 120:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.8
System's plan No. 8
TERMOPALEX WITH HEATING SYSTEM AND BOILER FOR THE PRODUCTION
SCHEMA N. 8
OF HOT SANITARY WATER
Functioning
:
The pump1 is on at the threshold A01.
If the fireplace works
The 3 outputs valve is commutated to the accumulation until the value of the
parameter A04 (probe2). The parameter A05 (probe2) is the value of the new
commutation in phase of decrease of the temperature probe2.
The 3 outputs valve with spring return is normally to the distribution system.
Make sure the accumulation has a security dissipation.
Used IN/OUT
Probe1
Probe1
Pompa1
Pompa
Probe2
Probe2
3 outputs valve
AUX
Parameter
C- -
A10
P01
P02
Parameter
A01
A04
A05
I01
I04
I05
Pag.: 58/60
C1:controller
S1
(threshold A01),
SERIGRAPHY
CONNECTORS
15 - 16
13 - 14
17 - 18
6 - 7
INSTALLER'S MENU PARAMETERS' SET (Par. 3.5)
System's configuration
Alarm thermostat
Probe's type: '0' =10K blue; '1' 100K grey
Activation output's AUX (6-7) protection functions
Parameters USER'S MENU (Par. 5.0)
Starting threshold pump1
Extinguishing threshold 3 outputs valve
Re-starting threshold 3 output valve
Thermostat hysteresis parameter A01
Thermostat hysteresis parameter A04
Thermostat hysteresis parameter A05
P1
System's symbol
Description
Description
Cod. 004770370
S2
BOILER
V1: 3 outputs valve
S1
1 2 3 4 5 6 7 8 9 10 11 12 13 14
P1
S2
V1
U.
Min Default
n
C01
°C
n
n
U.
Min Default
°C
°C
°C
°K
°K
°K
HSo
Hot
sanitary
water
HSi
Cold
sanitary
water
D
distribution
system
CONFIGURATION
C08
20 19 18 17 16 15
Max
C08
C08
60
85
90
0
0
1
0
0
1
Max
50
20
70
50
60
80
50
55
80
0
2
5
2
0
5
2
0
5
TC120
Tabla de contenido
loading

Tabla de contenido