3.3
ELECTRICAL CONNECTIONS
1
2
Name
Sonda1/Probe1 15 - 16
Sonda2/Probe2 17 - 18
FLUX
19 - 20
SCI
11 - 12
Pump/POMPA 13 – 14
SERV
3 - 4
AUX
6 – 7 – 8
3.4
ELECTRIC CONNECTION SPARK KIT
20 19 18 17 16 15
1
2
5 6 7 8 9 10
3.5
INSTALLER' S MENU (system's configuration chose)
It allows to modify the system's functioning according to the system's type
To enter the menu push together
The display shows the changing
To chose the installer's parameter use the buttons
To show the installer's parameter's value push the button
To modify the installer's parameter value push together
To show the list again and save the parameter push the button
To show the list of the parameters without modifying push the button
To exit the menu wait 5 seconds or push
Symbol
C- -
System's configuration
A10
Alarm thermostat
P01
Probe type (10K blue 0– 100K grey 1)
P02
Start output's AUX (6-7) protection functions
Symbol
A09
Anti freezing thermostat
T02
Anti block Timer
T03
Activation anti block pump timer
4.0
CONNECTION PLAN
Here are some electric/ hydraulic plans. For the hydraulic plans are shown the electric connection plan and the functioning
parameters that the installer could modify.
For each installer's parameter 'Cxx' selected, where xx = 01 -- 08, is associated a hydraulic plan.
According to the plan selected are activated the outputs and are controlled specific inputs.
Pag.: 50/60
20 19 18 17 16 15
3
4
5 6 7 8 9 10
11 12 13 14
Connectors
Pump 1 temperature probe
Temperature probe AUX
Flowswitch consent
SPR kit spark
Pump output
PULS kit Spark
Pump output / Valve 3 outputs 230 Vac 150 W Max
Table 1 - Legend command INPUTS / OUTPUTS
If your product doesn't interface with the spark kit read the further paragraph.
Connect the contact PULS of the spark kit to connectors 3-4
Connect the contact SPR of the spark kit to connectors 11-12
13 14
Fig..3 – Electric connections SPARK KIT
and
Description
Description INSTALLATOR' S Menu
Table 2 –
Description
Builder's parameters NOT CHANGEABLE
Table 3 –
All the outputs and the inputs of the probes are
automatically activated according to the type of the
system.
For the electrical connections
It is necessary to refer to the paragraph 4.1 for the
system's plan and to 4.2 for the electrical connection
system.
The probe and line's cables have to be separated
Fig. 2 – Electrical connections
Devices
Characteristics
Silicone cable
Functioning temperature: -50°C / 125 °C
Measure: 0 – 100 °C ± 1°C
Contact ON/OFF
Input230 Vac
230 Vac 150 W Max
Free contact: COM. - N. A.
for about 5 second.
MENU
MENU
Cod. 004770370
MENU
Min Default
U
n
C01
°C
60
n
0
n
0
U
°C
h
sec
Max
C01
C08
85
90
0
1
0
1
Default
4
24
30
TC120