See the PowerFlex 40 User Manual for more information on parameters.
= Stop drive before changing this parameter.
No.
Parameter
P037 [Stop Mode]
Active stop mode for all stop sources [e.g. keypad,
run forward (I/O Terminal 02), run reverse (I/O
Terminal 03), RS485 port] except as noted below.
Important: I/O Terminal 01 is always a coast to
stop input except when P036 [Start Source] is set
for "3-Wire" control. When in three wire control, I/O
Terminal 01 is controlled by P037 [Stop Mode].
P038 [Speed Reference]
Sets the source of the speed reference to the
drive.
Important: When A051 or A052 [Digital Inx Sel] is
set to option 2, 4, 5, 6, 13 or 14 and the digital
input is active, A051, A052, A053 or A054 will
override the speed reference commanded by this
parameter. Refer to Chapter 1 of the PowerFlex 40
User Manual for details.
P039 [Accel Time 1]
Sets the rate of accel for all speed increases.
P040 [Decel Time 1]
Sets the rate of decel for all speed decreases.
P041 [Reset To Defalts]
Resets all parameter values to factory defaults.
P042 [Voltage Class]
Sets the voltage class of 600V drives.
P043 [Motor OL Ret]
Enables/disables the Motor Overload Retention function.
Min/Max
Display/Options
0/9
0 = "Ramp, CF"
1 = "Coast, CF"
2 = "DC Brake, CF"
3 = "DCBrkAuto,CF"
4 = "Ramp"
5 = "Coast"
6 = "DC Brake"
7 = "DC BrakeAuto"
8 = "Ramp+EM B,CF"
9 = "Ramp+EM Brk"
(1)
0/7
0 = "Drive Pot"
1 = "InternalFreq"
2 = "0-10V Input"
3 = "4-20mA Input"
4 = "Preset Freq"
5 = "Comm Port"
6 = "Stp Logic"
7 = "Anlg In Mult"
0.0/600.0 Secs
0.1 Secs
0.1/600.0 Secs
0.1 Secs
0/1
0 = "Ready/Idle"
1 = "Factory Rset"
2/3
2 = "Low Voltage" (480V)
3 = "High Voltage" (600V)
0/1
0 = "Disabled"
1 = "Enabled"
(1)
(1)
(1)
(1)
Stop input also clears active fault.
English-15
Default
0
0
1 (IP66, Type 4X)
10.0 Secs
10.0 Secs
0
3
0