PLUMBING - GRAVITY DRAIN
4. Remove the clamp and barbed elbow and take
off the plastic cover in the base pan below the
drain hose.
the drain hose, securing with the supplied hose
clamp.
lying on the floor of the base pan until the unit is
positioned over the floor drain.
tube through the base pan into the floor drain or
lower back panel and connect to barbed elbow
and secure with clamp.
drain.
Water Supply
may also be used. Install an easily accessible shut-
off valve between the supply and the unit. This shut-
off valve should not be installed behind the unit.
The water connection is at the back of the cabinet.
Connect using a compression fitting, one is supplied
tied to the water inlet tube at the back of the cabinet.
When built in: Coil enough tubing behind the
machine so it can be pushed into the cavity without
kinking the tubing.
49-1000436 Rev. 0
Installation Instructions
(cont)
Connect water supply here, fitting is
supplied in bag tied to tube.
PLACEMENT OF THE ICE MACHINE
The ice machine is supplied with a power cord.
Do not remove the grounding pin from the cord's
Connect the machine so its own 115v, 15amp
circuit.
1. If the electrical outlet for the ice maker is behind
the unit, plug it into the unit.
2. Position the unit in the installation opening.
3. Turn on the water supply. Make sure that the
icemaker is plugged in and the power is on.
4. Slide the unit into the installation opening, paying
special attention to water supply and drain
connections. Do not kink!
5. Pour a couple of quarts of water into the ice
the drain pump should start and water should
pump out. Check for leaks.
6. Replace the service access panel.
in the hardware packet that can snap onto the
leveling legs if they are going to show when the
unit is level.
15