ATX/ATX2-R31-E-PH5-xx
ATX/ATX2-S31-E-PH5-xx
ATX/ATX2-R31-E-Le2-xx
1
2 3 4 5 6
0 Vdc
+Vcc
Code / D0
Data / D1
Clock
Terminal block Connector
Use an AC/DC power supply type LPS, Limited Power Source (as per IEC/UL/EN 60950-1 Ed2) or type ES1, PS1 (according to IEC/UL/EN
62368-1) for the
Main power supply:
Communication:
RS485 (L+ & L-) / RS232 (TD & RD) / TTL (Wiegand / Clock & Data)
Protection:
IP65, excluding connectors
The operating mode for the Buzzer and LED 1 and 2 can be programmed by a configuration card (R3x & S3x) or controlled by the remote system
with a 0 Vdc respectively on the "Led 1", "Led 2" and "Buzzer" inputs of the reader's connector or controlled by the communication protocol of
the reader (W3x).
Tearing is detected by an accelerometer. When the reader is wrenched, the switch output (connector J2) provides an O/C contact to indicate
the tearing of reader.
▪
for R/S 31: the wrenching signal will be emitted on the "Data/Data1" line. This function is configurable via a configuration card.
for R/S 32/33 and OSDP
▪
▪
for W 32/33: the reader will perform the operations configured with the SSCP
Caution: switch on the reader when it is in its final position to initialize the accelerometer in the correct position.
LEGIC readers are configurable by serial link for non-secure parameters and by master card SAM to access secure data on user's card.
Reader retrieve configuration from SAM at any time.
If the SAM is accepted, LED lights green, maintain the SAM in front of the reader until the buzzer beeps 5 times.
-
If the SAM is not accepted, LED lights red and buzzer is activated 1s.
-
Mifare® R & S readers are configurable with the SCB configuration card created with SECard,
OSDP
TM
readers are configurable with OCB configuration card:
If the SCB/OCB is compatible with the reader's firmware, the LED lights green, and the buzzer beeps five times.
-
If the SCB/OCB is not compatible with the reader's firmware, the LED lights red, and the buzzer is activated for 1 s.
-
If the SCB/OCB key is different from the reader's key: no reaction.
-
Caution: set your reader with your own company key.
▪ The supply voltage at the reader's connector should be between +7 Vdc and +28 Vdc.
▪ Recommended distance between two readers: parallel plane: 11.8 in – same plane: 15.8 in – perpendicular plane: 9.8 in.
▪ Use a ferrite (two-way) for the cable (power supply and data). Example: reference 74271222 WURTH ELEKTRONIK.
For data signals, 10k pull-up resistors are connected internally to Vin (power supply voltage) for optimal wiring distances.
ATEX & IECEX reader
Installation procedure
ATX/ATX2 13.56MHz MIFARE® & LEGIC
7 8 9 10
0 Vdc
Buzzer
+Vcc
Led 2
Led 1
Type x31
(Wiegand)
1
2
3
Data 0 (D0)
4
Data 1 (D1)
5
Clock
6
NC
NC
7
8
9
10
Range +7 Vdc up to +28 Vdc
TM
: the reader will perform the operations configured with the configuration card.
© STid - 20 PA des Pradeaux FR13850 Gréasque – NI1104X03 - Page 5 sur 18 - Ed. 20/01/2021
Lecteur ATEX & IECEX
Notice d'installation
ATX/ATX2-R32-E-PH5-5AB
ATX/ATX2-S32-E-PH5-5AB
ATX/ATX2-W32-E-PH5-5AA
ATX/ATX2-R32-E-Le2-5AB
ATX/ATX2-W32-E-Le2-5AA
1
2 3 4 5 6
7 8 9 10
Buzzer
Led 2
Led 1
Tx
Rx
Type x31
(Clock & Data)
0 Vdc
+Vcc (+7 Vdc / +28 Vdc)
Code
Data
Clock
NC
NC
Led 1
Led 2
Buzzer
Power Supply Characteristics
Typical: +12 Vdc
Characteristics
Buzzer / LED
Anti-Tearing
Reader configuration
Precautions for installation
TTL pull-ups
ATEX & IECEX lectores
Manual de instalación
ATX/ATX2-R33-E-PH5-7AB
ATX/ATX2-S33-E-PH5-7AB
ATX/ATX2-W33-E-PH5-7AA
ATX/ATX2-W33-E-Le2-7AA
ATX/ATX2-W33-E-PH5-7OS
1
2 3 4 5 6
0 Vdc
+Vcc
L+
L-
Type x32
Type x33
(RS232)
(RS485)
NC
NC
NC
Tx
Rx
®
protocol.
US
FR
ES
7 8 9 10
Buzzer
Led 2
Led 1
NC
NC
NC
L +
L -