WATER CONNECTIONS
WARNING!
The machine must be connected to the water
mains using new hose-sets. The old hose-
sets should not be reused !
Water installation must have the following
characteristics:
Temperature:
10÷12
Dynamic Pressure :
1) Connect the end of drain pipe "S" (fig.3 -
pag.46) th the drainage shaft.
Drain pipe should have slump to allow the
matters drain; under floor drain pipes should
have a dia. of 80-100 mm.
2) Connect inlet pipe "E" (fig.3 - pag.46) to a
3/4" screwed Gas tap .
Make sure there are no throttlings along the
pipe.
The National and Regional Standards existing
on the subject must be rigorously respected.
Parameters' programming
modification
B
G
A
°C
2 ÷ 4 bar (200÷400 kPa)
C
START
D
E
F
1. Make sure that the wall switch is on;
2.
Press at the same time buttons "E" and
"G" ("+" and "-") and then give power to
the machine by pressing button ''A'' to
position On;
3.
Always pressing buttons "E" and "G"
("+" and "-"), wait for 3 seconds till on
the display ''FACTORY PARAMETERS''
and then ''Language'' will appear;
4.
Modify the parameter acting on buttons
"E" and "G" ("+" and "-") to reduce or
increase the parameter value;
5.
Press button ''C'' (START) to see in
sequence all the parameters ( look at the
complete list in the following table);
6.
To validate the modified parameters'
value, run by button ''C'' (START) till the
last inscription ''Press start'' will appear;
The parameters are stored.
Description
Language
Italian
French
Spanish
English
German
Time-out
Lev. 1-2
Time-out
Lev. 3
Rinse cycle
(yes-not)
Total CYCLES
RESET Electronic card :
Press at the same time the 3 buttons ''B'', ''C''
and '"+" (''E'') and always pressing them give
power to the machine by pressing button ''A''
to the position On.
52
Default
Modified
(Reset)
parameters
Italian
2s
DO NOT
MODIFY
30s
DO NOT
MODIFY
Yes
___
Cycles' meter