Replacement Parts List
Part Number
Description
1
SDO180W
PENDENT COUPLING (WHITE)
2
RPFD2612
HOUSING TOP GASKET
3
RPFD709
HOUSING TOP
4
RP70VL2008
POE POWER PCB
5
RPFD702
24VAC HEATER
6
RPFD060
CAMERA BRACKET
7
RPPKH6063
SPACERS
8
RPFDO80
12VDC BLOWER
9
RPLEDR02
LED
10
RP70SW07
CALIBRATION SWITCH
11
RPVL4138
PLASTIC CAP
12
RPVL4101
QUICK RELEASE BRACKET
13
N/A
CAMERA
14
RPFD703
CLAMPING RING
15
RP96GK2558
DOME GASKET
16a RPFD7C
CLEAR DOME
16b RPFD7T
TINTED DOME
17
RPFD701
TRIM RING
N/S RPPKE1110
ELECTRICAL PACKET
To Re-calibrate the Enclosure:
RED button
(restore settings)
To restore the software to its original factory default
settings, press and hold the RED button for 5 or more
seconds. Re-calibration should only be required if you
signi cantly charge the camera system.
EXAMPLES INCLUDE:
1. Move dome to another location
2. Replace ER_EP camera
3. Upgrade the system wiring or connectors
6
7
8
12
15
16
17
1
2
3
4
5
9
10
11
13
14