INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
7e
ALARM
SANICONDENS
Best is fitted with a detection system
®
that can trigger an alarm if the water level rises too high
(audible or visual alarm, 1.5V to 230V), see diagram
1
. Brown wire: shared wire
2
. Black wire: normally off
3
. Blue wire: normally on
To fit the alarm, connect the blue and brown wires
of the alarm to the respective terminals on the
SANICONDENS
Best.
®
OPTIONAL:
if you connect the brown and black wires to
the control relays on your boiler, it will be switched off if the
water level rises too high in the unit.
ATTENTION:
The maximum current admissible for our
detection system is 0.5A
To protect the electrical components in the
SANICONDENS
Best, once the alarm has been triggered,
®
any water continuing to fill the tank comes out through the
overflow outlets in the cover.
7f
EXAMPLE OF AN INSTALLATION OF A SANICONDENS
Best: see fig.
7f
8
UNIT MAINTENANCE
Check the state of the pellets regularly.
Replace the pellets once a year. When replacing the
pellets, also clean the neutraliser drawer.
9
STANDARDS
SANICONDENS
Best conforms to the European directive
®
89/336/CEE on electrical safety.
INSTRUCTIONS INTENDED SOLELY FOR
QUALIFIED PROFESSIONALS
10
DISASSEMBLY
If a breakdown occurs, any service on the unit should be
carried out by a qualified engineer. In particular the
replacement of the power cable.
Disconnect the electrical supply before carrying out
work on the unit.
11
TROUBLESHOOTING
INSTRUCTIONS RESERVED SOLELY FOR
QUALIFIED PROFESSIONALS
7e
:
Disconnect the electrical supply before carrying out any work.
FAULT DETECTED
• The pump does not start
• The pump does not lift
®
12
GUARANTEE
SANICONDENS
parts and labour, subject to correct installation and use of
the unit.
PROBABLE CAUSES
• The pump is not
• Plug in the unit.
connected to the power
supply
• Power cut
• Check the mains voltage.
• Float blocked
• Clean the SANICONDENS
Best tank.
• Condensates inlet pipe
• Clean the SANICONDENS
blocked
Best inlet pipe.
• Neutralisation drawer is
• Clean the drawer,
blocked
replace the pellets
• Non-return valve blocked
• Clean the valve.
• Discharge pipe blocked
• Clean the discharge pipe.
Best SFA is guaranteed for 2 years for
®
ACTION NEEDED
®
®