  • Página 1 STREET PANELS AND DIGITAL AUDIO CONTROL GROUPS WITH VIEWER REF. G3230 AND REF. G3240 GUÍA DE INSTALACIÓN INSTALLATION GUIDE...
  • Página 2 ÍNDICE. INDEX. Introduction to the Digital Guinaz System Capacity of the Digital Guinaz System Installation of street panels Street panel modular system: Inserting modules Placement of the name tags Street panel installation Placement of the name tag in the viewer...
  • Página 3 1. INTRODUCCIÓN AL SISTEMA DIGITAL GUINAZ. INTRODUCTION TO THE DIGITAL GUINAZ SYSTEM. The wiring of the digital Guinaz system is made up of a 3-wire bus for the audio and data signals and power supply, with which all the equipment of the installation can interconnect. These three wires can be of any type readily available in the market.
  • Página 4 Guinaz catalogue to make up the street panel. These modules are delivered individually and the client will assemble them to form the panel.
  • Página 5 • Street panel with telephone number pad. - If a video signal is required, there are street panel models that include a camera. This camera will also be different according to the type of monitor installed in the dwellings: black and white, colour hands-free, or colour monitors with telephone (or colour EXPAND).
  • Página 6 2. CAPACIDAD DEL SISTEMA DIGITAL GUINAZ. CAPACITY OF THE DIGITAL GUINAZ SYSTEM. The digital Guinaz system can handle up to: • 63 External accesses. • 63 Main internal accesses. • 63 Secondary internal accesses per main internal access. • 255 Dwellings per main internal access.
  • Página 7 Apart from the main internal access (PIP), a maximum of 63 secondary internal accesses (PIS) and up to 255 dwellings can be connected to each internal dwelling bus, since the telephones/monitors can be configured with a number between 1 and 255. There may be several telephones or monitors in each dwelling, depending on the number of power supplies installed.
  • Página 8 Put the upper frame in place and tighten both screws. Assemble the audio control group and the camera group in their corresponding modules. Execute the connections with straps between: - Audio control unit and camera unit. - Audio control unit and first push button module.
  • Página 9 3.3 INSTALACIÓN PLACA CALLE. INSTALLATION OF THE STREET PANEL. To open towards the right. Unscrew left Assembly the flush Attach the street panel screw and loosen the right one. mounted box. using two screws. Move the street panel 1.5 mm to the left and the front. Open the street panel.
  • Página 10 3.4 COLOCACIÓN ETIQUETA EN VISOR. PLACEMENT OF THE NAME TAG IN THE VIEWER. Extract the audio group from the street panel. Press on the parts indicated to remove the viewer. Extract the audio group by levering with a screwdriver. Parts to be pressed. Separate the translucent glass part, insert name tag and replace the translucent glass part.
  • Página 11 WHEN INSTALLING THE STREET PANEL FOR THE FIRST TIME, THE UPPER AND LOWER COVERS MUST BE ASSEMBLED BEFORE CLOSING IT (SEE POINT 3.3). PRESS THE COVERS OVER THE FRAMES UNTIL THEY CLIP IN. THE UPPER AND LOWER COVERS CAN ONLY BE ATTACHED OR REMOVED WHEN THE STREET PANEL OPEN.
  • Página 12 The power for the system is supplied via the cables joining terminal blocks 1 and 2 of the power supply with terminal blocks 1P and 2P of the street panel audio control group. The communications bus is formed by the three cables leaving from terminal blocks 1M, 2M and 3M of the street panel audio control group, which will be connected, respectively, to terminal blocks 1M, 2M and 3M of the telephones in the dwellings.
  • Página 13 The connection of audio/data between the main internal and external accesses is made with the cables connected to terminal block 3P of each street panel. The cables joining the different terminal blocks 1P , 2P and 3P constitute the external bus of the street panels.
  • Página 14: Esquema Para Un Bloque De Viviendas Con Un Acceso En Instalación

    In all cases, the distributor will only receive power supply when one of the monitors (or street panels) connected to it is operating. All distributors have a resistance at the end of the line that will be broken if the distributor is not the last one along its distribution branch;...
  • Página 15 The connection between the street panel and the door opener is executed through two cables (NO bushing insulators and – audio control unit). Bushing insulators +12 and C are to be connected between each other with a cable. An external push button can also be connected to bushing insulators C and NO of the audio control unit to activate the door opener.
  • Página 16 4.6 ESQUEMA PARA UN BLOQUE DE VIVIENDAS CON DOS ACCESOS EN INSTALACIÓN VÍDEO. DIAGRAM FOR A BLOCK OF DWELLINGS WITH TWO ACCESSES IN VIDEO INSTALLATION. M1934 POWER SUPPLY CABLE. SIGNAL CABLE. Do no shut-off the resistance COAXIAL CABLE. F1330 M1934 Shut-off the resistance Configuration for Configuration for...
  • Página 17 The communications bus is formed by the three cables leaving from terminal blocks 1M, 2M and 3M of the street panel audio control group, which will be connected, respectively, to terminal blocks 1M, 2M and 3M of the secondary street panel and the telephones in the dwellings.
  • Página 18 The street panels of the two external accesses have a power supply. The equipment of the two blocks of dwellings has one power supply per block. The cables leaving terminal blocks 1 of power supplies must never be connected to each other. However, the cables leaving terminal blocks 2 of power supplies must be connected to each other as they are the ground for the system.
  • Página 19 4.9 CONEXION DE ABREPUERTAS DE CORRIENTE ALTERNA. CONNECTION OF ALTERNATING CURRENT DOOR-OPENER. Digital audio control units G3230 and G3240 are ready for the connection of alternating current door openers. The connection between the street panel and the door opener is executed in a different manner and a F1318 power source will have to be added.
  • Página 20 maximum cable length (Lmax) number of dwellings section of the cable one telephone one monitor INSTALACIONES DIGITALES DE AUDIO DIGITAL AUDIO INSTALLATIONS MAX LENGTH Lmax (meters) CABLE SECTIONS NUM. DWELLINGS (max) PREMISES One telephone per dwelling. One power supply beside each street panel (Note 1).
  • Página 21 INSTALACIONES DIGITALES DE VIDEO DIGITAL VIDEO INSTALLATIONS MAX LENGTH Lmax (meters) CABLE SECTIONS NUM. DWELLINGS (max) PREMISES COLOUR MONITORS MONITORS One telephone per dwelling. One power supply beside each street panel (Note 1). Note 1: It is considered that a Power Supply is beside a Street Panel when the cable length joining them is less than: - 2.5 meters for 0.22mm²...
  • Página 22 How to obtain the maximum length in installations in which there is more than one telephone/monitor per dweling is indicated in the following table, with said table being based on the previous simplified table for video installations. FACTORES DE CORRECCIÓN PARA INSTALACIONES DE VIDEO CON MÁS DE UN MONITOR POR VIVIENDA CORRECTION FACTORS FOR VIDEO INSTALLATIONS WITH MORE THAN ONE MONITOR PER DWELING...
  • Página 23 TYPE OF STREET PANEL TYPE OF ACCESS PROGRAMMING METHOD POSSIBLE TYPES OF CALL MICROSWITCHES INTERNAL STANDARD: (pre-programmed: pushbutton nº = dwelling nº. It is recommended the Installer Tables are used). MODULAR WITH VIEWER EXTERNAL NOT VALID - STANDARD INTERNAL MICROSWITCHES TELEPHONE NUMBER PAD - STANDARD 1+2 WITH VIEWER...
  • Página 24 SECONDARY INTERNAL ACCESS No. 2 SECONDARY INTERNAL SECONDARY INTERNAL ACCESS No. 1 ACCESS No. 1 INTERNAL DWELLINGS BUS INTERNAL DWELLINGS BUS MAIN INTERNAL ACCESS No. 1 MAIN INTERNAL ACCESS No. 2 STREET PANEL EXTERNAL BUS MAIN EXTERNAL ACCESS No. 1 MAIN EXTERNAL ACCESS No.
  • Página 25 MICROSWITCH 1 OPTION 1. CONFIGURATION OF THE ACCESS CODE: CONFIGURATION OF THE ACCESS CODE. NORMAL FUNCTIONING IMPORTANT: THE ACCESS CODE CAN ONLY BE CONFIGURED IN STREET PANELS WITH A TELEPHONE NUMBER PAD. Process to be followed: a) Set microswitch 1 to the ON position and the red LED of the telephone number pad will light up.
  • Página 26 MICROSWITCH 2. BUTTON CONFIGURATION: PUSHBUTTON MODULES TELEPHONE NUMBER PAD IMPORTANT: ONLY STREET PANELS WITH VIEWER HAVING A TELEPHONE NUMBER PAD MAY BE USED FOR EXTERNAL ACCESSES. Street panels with viewer in internal accesses may use any of the two types of buttons. When the street panel is external, the LEDs of the telephone number pad will light up intermittently to warn of an error if the type of buttons is not configured correctly.
  • Página 27 Microswitch No. 4 in “ON” position: The call can be type 1+3 or type 2+3. Call 1+3. The four corresponding digits are pressed: nº placa calle nº vivienda street panel No. dwelling No. • Llamada 2+2. Se marcan cinco dígitos que corresponden: Call 2+2.
  • Página 28 7. PUESTA EN MARCHA Y SOLUCIÓN DE PROBLEMAS. START UP AND SOLVING PROBLEMS. This section explains the ways to solve incidents that may occur during the installation, maintenance and repair of digital Guinaz systems. However, our Technical Assistance Service is always available for you to solve any doubt or problem that may arise.
  • Página 29 Check the voltages in the following bushing insulators of the audio control unit: 1M – 2M = 17Vdc 3M – 2M = 17Vdc If voltages are correct and the problem persists, then the audio control unit might be broken. In the case that any of the above-mentioned voltages do not correspond to that indicated, disconnect cables 1M, 2M and 3M of the audio control unit and verify again.
  • Página 30 Check that the connection strap between the audio control unit and the camera is correctly connected. Verify correct configuration of the street panel (micro-switches of the audio control unit). Check that the installed cable complies with the following technical specifications: 75 ohm impedance coaxial cable or cat.
  • Página 31 If a direct current door opener has been installed, check the NO cables and – (GND) door opener connection, and that bushing insulators +12 and C are connected with a cable. In the case of these cables being correctly installed and in a good state, then the breakdown could be located in the door opener itself.