NOCO Genius G3500 Guia Del Usuario página 4

Ocultar thumbs Ver también para G3500:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 29
Mode
6V
NORM
Press & Hold
12V
LITHIUM
Press & Hold
12V
REPAIR
Press & Hold
Using 6V NORM. [Press & Hold]
6V NORM charge mode is designed for 6-volt lead-acid
batteries only, like Wet Cell, Gel Cell, Enhanced Flooded,
Maintenance-Free and Calcium batteries. Consult the
battery manufacturer before using this mode.
CAUTION. THIS MODE IS FOR 6-VOLT LEAD-ACID
BATTERIES ONLY.
Using 12V Lithium. [Press & Hold]
12V Lithium charge mode is designed for 12-volt lithium-ion
batteries only, including lithium iron phosphate.
CAUTION. USE THIS MODE WITH CARE. THIS MODE
IS FOR 12-VOLT LITHIUM BATTERIES ONLY. LITHIUM-
ION BATTERIES ARE MADE AND CONSTRUCTED
IN DIFFERENT WAYS AND SOME MAY OR MAY NOT
CONTAIN A BATTERY MANAGEMENT SYSTEM (BMS).
CONSULT THE LITHIUM BATTERY MANUFACTURER
BEFORE CHARGING AND ASK FOR RECOMMENDED
CHARGING RATES AND VOLTAGES. SOME LITHIUM-ION
For charging 6-volt Wet Cell, Gel Cell,
Enhanced Flooded, Maintenance-Free
and Calcium batteries. When selected, a
white LED will illuminate.
7.25V | 3.5A | 2-120Ah Batteries
For charging 12-volt lithium-ion batteries,
including lithium iron phosphate. When
selected, a blue LED will illuminate.
14.2V | 3.5A | 2-120Ah Batteries
An advanced battery recovery mode
for repairing and storing, old, idle,
damaged, stratified or sulfated
batteries. When selected, a red LED will
illuminate and flash
16.5V | 1.5A | Any Capacity
Explanation
Tabla de contenido
loading

Tabla de contenido